    Source: Journal of Water Resources Planning and Management:;2018:;Volume ( 144 ):;issue: 003
    Author:
    Jahanpour Mohammadamin;Tolson Bryan A.;Mai Juliane
    DOI: 10.1061/(ASCE)WR.1943-5452.0000875
    Publisher: American Society of Civil Engineers
    Abstract: Two implementations of the Pareto archived dynamically dimensioned search (PADDS) algorithm using different selection metrics are applied to 12 water distribution network (WDN) design benchmark problems from the literature. Convex hull contribution (CHC) and hypervolume contribution (HVC) are used as selection metrics for PADDS making this study the first to assess their relative performance on WDN design problems. Past research applied five state-of-the-art multiobjective evolutionary algorithms (MOEAs) to these 12 benchmark problems to generate the best-known Pareto fronts (PFs). The PADDS-CHC and PADDS-HVC both find all solutions on the known true PFs of the first three problems. Together, both PADDS results augment the previously best-known PFs in the nine other benchmark problems with new PF solutions, some of which dominate previous best-known PF solutions, to define updated best-known PFs. Comparative results against five state-of-the-art MOEAs show PADDS derived best-known PFs are equal or better than all other algorithms in 11 of 12 WDN design problems. A comprehensive comparison between PADDS-CHC and PADDS-HVC performance on the largely convex benchmark problem Pareto fronts reveals the different responses of PADDS algorithm to increment of computational budget. An innovative measure called effective archive size (EAS) is introduced to quantify the portion of PADDS archived solutions that play the dominant role in directing PADDS toward the final PF. Tracking the EAS value throughout the search revealed that compared with PADDS-HVC, the EAS of PADDS-CHC is typically close to an order of magnitude smaller. In fact, the PADDS-CHC algorithm generates candidate solutions from a surprisingly small effective archive size that ranges from only 16 to 73 solutions across the 12 benchmark WDN problems while being only 24 for the largest problem.
    • Download: (1.584Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4249920
    Collections
    • Journal of Water Resources Planning and Management

    Show full item record

    contributor authorJahanpour Mohammadamin;Tolson Bryan A.;Mai Juliane
    date accessioned2019-02-26T07:51:56Z
    date available2019-02-26T07:51:56Z
    date issued2018
    identifier other%28ASCE%29WR.1943-5452.0000875.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4249920
    description abstractTwo implementations of the Pareto archived dynamically dimensioned search (PADDS) algorithm using different selection metrics are applied to 12 water distribution network (WDN) design benchmark problems from the literature. Convex hull contribution (CHC) and hypervolume contribution (HVC) are used as selection metrics for PADDS making this study the first to assess their relative performance on WDN design problems. Past research applied five state-of-the-art multiobjective evolutionary algorithms (MOEAs) to these 12 benchmark problems to generate the best-known Pareto fronts (PFs). The PADDS-CHC and PADDS-HVC both find all solutions on the known true PFs of the first three problems. Together, both PADDS results augment the previously best-known PFs in the nine other benchmark problems with new PF solutions, some of which dominate previous best-known PF solutions, to define updated best-known PFs. Comparative results against five state-of-the-art MOEAs show PADDS derived best-known PFs are equal or better than all other algorithms in 11 of 12 WDN design problems. A comprehensive comparison between PADDS-CHC and PADDS-HVC performance on the largely convex benchmark problem Pareto fronts reveals the different responses of PADDS algorithm to increment of computational budget. An innovative measure called effective archive size (EAS) is introduced to quantify the portion of PADDS archived solutions that play the dominant role in directing PADDS toward the final PF. Tracking the EAS value throughout the search revealed that compared with PADDS-HVC, the EAS of PADDS-CHC is typically close to an order of magnitude smaller. In fact, the PADDS-CHC algorithm generates candidate solutions from a surprisingly small effective archive size that ranges from only 16 to 73 solutions across the 12 benchmark WDN problems while being only 24 for the largest problem.
    publisherAmerican Society of Civil Engineers
    typeJournal Paper
    journal volume144
    journal issue3
    journal titleJournal of Water Resources Planning and Management
    identifier doi10.1061/(ASCE)WR.1943-5452.0000875
    page4017099
    treeJournal of Water Resources Planning and Management:;2018:;Volume ( 144 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian