    Performance of Precast Concrete Substructures with Dry Connections to Resist Progressive Collapse

    Source: Journal of Performance of Constructed Facilities:;2018:;Volume ( 032 ):;issue: 002
    Author:
    Qian Kai;Li Bing
    DOI: 10.1061/(ASCE)CF.1943-5509.0001147
    Publisher: American Society of Civil Engineers
    Abstract: In the current study, three one-third scaled beam-slab substructures comprising a cast-in-place reinforced concrete specimen and two precast concrete (PC) specimens were tested under a pushdown loading regime to investigate the effects of connection types on the behavior of PC structures to mitigate progressive collapse. A special link was designed to enhance the connection between PC slabs and PC beams. The test results, including load-displacement curves, ultimate load capacity, ultimate deformation capacity, and local strains, are presented. The failure mode and mechanisms of load redistribution are further discussed. It is demonstrated that the PC specimen with welded connections achieved brittle failure with the lowest ultimate load capacity and deformation capacity. Although the lowest initial stiffness and first peak load capacity were achieved in the PC specimen with pinned connections, its large rotational ability ensured that the specimen failed in a ductile manner, which allowed the development of considerable tensile membrane actions. The main source of the membrane action was from the reinforcement mesh in the topping layer. Despite severe separations occurring between the PC slabs and beams, no PC slab collapsed even though the maximum displacement was larger than double the beam span.
    • Download: (2.176Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Performance of Precast Concrete Substructures with Dry Connections to Resist Progressive Collapse

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4248776
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorQian Kai;Li Bing
    date accessioned2019-02-26T07:41:46Z
    date available2019-02-26T07:41:46Z
    date issued2018
    identifier other%28ASCE%29CF.1943-5509.0001147.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4248776
    description abstractIn the current study, three one-third scaled beam-slab substructures comprising a cast-in-place reinforced concrete specimen and two precast concrete (PC) specimens were tested under a pushdown loading regime to investigate the effects of connection types on the behavior of PC structures to mitigate progressive collapse. A special link was designed to enhance the connection between PC slabs and PC beams. The test results, including load-displacement curves, ultimate load capacity, ultimate deformation capacity, and local strains, are presented. The failure mode and mechanisms of load redistribution are further discussed. It is demonstrated that the PC specimen with welded connections achieved brittle failure with the lowest ultimate load capacity and deformation capacity. Although the lowest initial stiffness and first peak load capacity were achieved in the PC specimen with pinned connections, its large rotational ability ensured that the specimen failed in a ductile manner, which allowed the development of considerable tensile membrane actions. The main source of the membrane action was from the reinforcement mesh in the topping layer. Despite severe separations occurring between the PC slabs and beams, no PC slab collapsed even though the maximum displacement was larger than double the beam span.
    publisherAmerican Society of Civil Engineers
    titlePerformance of Precast Concrete Substructures with Dry Connections to Resist Progressive Collapse
    typeJournal Paper
    journal volume32
    journal issue2
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)CF.1943-5509.0001147
    page4018005
    treeJournal of Performance of Constructed Facilities:;2018:;Volume ( 032 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian