YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Experimental Research on PBL Connectors Considering the Effects of Concrete Stress State and Other Connection Parameters

    Source: Journal of Bridge Engineering:;2018:;Volume ( 023 ):;issue: 001
    Author:
    Xuewei Wang
    ,
    Bing Zhu
    ,
    Shengai Cui
    ,
    Eric M. Lui
    DOI: 10.1061/(ASCE)BE.1943-5592.0001158
    Publisher: American Society of Civil Engineers
    Abstract: The perforated rib shear [Perfobond Leiste in German (PBL)] connector is a type of shear connector used in some steel–concrete composite bridges as a main load-transfer element between the concrete roadway and the supporting steel deck. The shear capacity of PBL connectors is affected by several connection parameters, such as the diameter of the transverse steel reinforcement, the size of the perforated rib hole, and the thickness of the rib plate, and the stress state in the surrounding concrete. In the present study, 33 test specimens were designed, and push-out tests were performed to investigate how these parameters affect the shear capacity of PBL connectors. The test results show that the shear capacity of these connectors increased with an increase in the diameter of the transverse reinforcing bar, an increase in the size of the rib holes, and an increase in thickness of the perforated rib plate. As for the effect of concrete stress state, it was found that the shear capacity of the connectors increased when a transverse compressive stress was present, but it decreased when a transverse tensile stress was present. Using results from these tests, a design equation that takes all of these factors into consideration in determining the shear capacity of PBL connectors is proposed. The proposed equation produces reasonably accurate results when compared with experimentally determined shear capacity for these connectors.
    • Download: (2.638Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Experimental Research on PBL Connectors Considering the Effects of Concrete Stress State and Other Connection Parameters

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4245245
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorXuewei Wang
    contributor authorBing Zhu
    contributor authorShengai Cui
    contributor authorEric M. Lui
    date accessioned2017-12-30T13:03:55Z
    date available2017-12-30T13:03:55Z
    date issued2018
    identifier other%28ASCE%29BE.1943-5592.0001158.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4245245
    description abstractThe perforated rib shear [Perfobond Leiste in German (PBL)] connector is a type of shear connector used in some steel–concrete composite bridges as a main load-transfer element between the concrete roadway and the supporting steel deck. The shear capacity of PBL connectors is affected by several connection parameters, such as the diameter of the transverse steel reinforcement, the size of the perforated rib hole, and the thickness of the rib plate, and the stress state in the surrounding concrete. In the present study, 33 test specimens were designed, and push-out tests were performed to investigate how these parameters affect the shear capacity of PBL connectors. The test results show that the shear capacity of these connectors increased with an increase in the diameter of the transverse reinforcing bar, an increase in the size of the rib holes, and an increase in thickness of the perforated rib plate. As for the effect of concrete stress state, it was found that the shear capacity of the connectors increased when a transverse compressive stress was present, but it decreased when a transverse tensile stress was present. Using results from these tests, a design equation that takes all of these factors into consideration in determining the shear capacity of PBL connectors is proposed. The proposed equation produces reasonably accurate results when compared with experimentally determined shear capacity for these connectors.
    publisherAmerican Society of Civil Engineers
    titleExperimental Research on PBL Connectors Considering the Effects of Concrete Stress State and Other Connection Parameters
    typeJournal Paper
    journal volume23
    journal issue1
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)BE.1943-5592.0001158
    page04017125
    treeJournal of Bridge Engineering:;2018:;Volume ( 023 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian