    Behavior of Hollow-Core FRP-Concrete-Steel Columns under Static Cyclic Flexural Loading

    Source: Journal of Structural Engineering:;2018:;Volume ( 144 ):;issue: 002
    Author:
    Omar I. Abdelkarim
    ,
    Mohamed A. ElGawady
    ,
    Sujith Anumolu
    ,
    Ahmed Gheni
    ,
    Gregory E. Sanders
    DOI: 10.1061/(ASCE)ST.1943-541X.0001905
    Publisher: American Society of Civil Engineers
    Abstract: This paper presents the seismic behavior of hollow-core fiber-reinforced polymer (FRP)-concrete-steel (HC-FCS) columns comparable with the conventional RC column. The typical HC-FCS column consists of a concrete shell sandwiched between an outer FRP tube and an inner steel tube. The HC-FCS column represents a compact engineering system; the steel and FRP tubes act together as stay-in-place formworks. The steel tube acts as a flexural and shear reinforcement. This paper studies three large-scale columns—one RC column having a solid cross section and two HC-FCS columns. Each column has an outer diameter of 610 mm (24 in.) and a shear span-to-diameter ratio of 4.0. The steel tube is embedded into the reinforced concrete footing with an embedded length of 1.6 times the steel tube diameter, whereas the FRP tube only confines the concrete shell and truncates at the top of the footing. The HC-FCS columns exhibits high lateral drift reaching 15.2% and fail gradually due to concrete crushing and local steel tube buckling, followed by FRP rupture. The reference RC column fails at a drift of 10.9% due to rebar fracture. Simple beam theory overpredicts the flexural strength of the columns by an average of 9%.
    • Download: (2.668Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Behavior of Hollow-Core FRP-Concrete-Steel Columns under Static Cyclic Flexural Loading

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4244584
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorOmar I. Abdelkarim
    contributor authorMohamed A. ElGawady
    contributor authorSujith Anumolu
    contributor authorAhmed Gheni
    contributor authorGregory E. Sanders
    date accessioned2017-12-30T13:01:10Z
    date available2017-12-30T13:01:10Z
    date issued2018
    identifier other%28ASCE%29ST.1943-541X.0001905.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4244584
    description abstractThis paper presents the seismic behavior of hollow-core fiber-reinforced polymer (FRP)-concrete-steel (HC-FCS) columns comparable with the conventional RC column. The typical HC-FCS column consists of a concrete shell sandwiched between an outer FRP tube and an inner steel tube. The HC-FCS column represents a compact engineering system; the steel and FRP tubes act together as stay-in-place formworks. The steel tube acts as a flexural and shear reinforcement. This paper studies three large-scale columns—one RC column having a solid cross section and two HC-FCS columns. Each column has an outer diameter of 610 mm (24 in.) and a shear span-to-diameter ratio of 4.0. The steel tube is embedded into the reinforced concrete footing with an embedded length of 1.6 times the steel tube diameter, whereas the FRP tube only confines the concrete shell and truncates at the top of the footing. The HC-FCS columns exhibits high lateral drift reaching 15.2% and fail gradually due to concrete crushing and local steel tube buckling, followed by FRP rupture. The reference RC column fails at a drift of 10.9% due to rebar fracture. Simple beam theory overpredicts the flexural strength of the columns by an average of 9%.
    publisherAmerican Society of Civil Engineers
    titleBehavior of Hollow-Core FRP-Concrete-Steel Columns under Static Cyclic Flexural Loading
    typeJournal Paper
    journal volume144
    journal issue2
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0001905
    page04017188
    treeJournal of Structural Engineering:;2018:;Volume ( 144 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian