    Evaluation of Sloped RBS Moment Connections

    Source: Journal of Structural Engineering:;2016:;Volume ( 142 ):;issue: 006
    Author:
    Dong-Won Kim
    ,
    Steven C. Ball
    ,
    Hyoung-Bo Sim
    ,
    Chia-Ming Uang
    DOI: 10.1061/(ASCE)ST.1943-541X.0001459
    Publisher: American Society of Civil Engineers
    Abstract: AISC 358 provides steel connections that are prequalified for use in special and intermediate moment frames (SMF and IMF). Implicit in this standard is that the beam and column are orthogonal to each other in the elevation of the frame. To evaluate the effects of a sloped connection considering an angle of deviation from orthogonal of 28°, two reduced beam section (RBS) moment connections with W36×231 beam and W36×302 column were cyclically tested. Although both specimens met the acceptance criteria of AISC 341, brittle fracture of top flange weld soon followed, a failure mode not typical of an RBS connection. Finite-element analysis demonstrated that the strain demand was not symmetric between two flanges. The strain demand at the heel location was higher than that at the opposite flange and increased with the angle of the slope. The AISC 341 welding requirement for steel backing removal, back-gouging, and fillet reinforcing should be linked to the heel and toe locations, not the top and bottom flanges, for a sloped connection. A preferred RBS configuration where the center of the RBS is perpendicular to the longitudinal axis of the beam, not parallel to the column as was used in the test specimens, was proposed.
    • Download: (3.654Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Evaluation of Sloped RBS Moment Connections

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4244492
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorDong-Won Kim
    contributor authorSteven C. Ball
    contributor authorHyoung-Bo Sim
    contributor authorChia-Ming Uang
    date accessioned2017-12-30T13:00:45Z
    date available2017-12-30T13:00:45Z
    date issued2016
    identifier other%28ASCE%29ST.1943-541X.0001459.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4244492
    description abstractAISC 358 provides steel connections that are prequalified for use in special and intermediate moment frames (SMF and IMF). Implicit in this standard is that the beam and column are orthogonal to each other in the elevation of the frame. To evaluate the effects of a sloped connection considering an angle of deviation from orthogonal of 28°, two reduced beam section (RBS) moment connections with W36×231 beam and W36×302 column were cyclically tested. Although both specimens met the acceptance criteria of AISC 341, brittle fracture of top flange weld soon followed, a failure mode not typical of an RBS connection. Finite-element analysis demonstrated that the strain demand was not symmetric between two flanges. The strain demand at the heel location was higher than that at the opposite flange and increased with the angle of the slope. The AISC 341 welding requirement for steel backing removal, back-gouging, and fillet reinforcing should be linked to the heel and toe locations, not the top and bottom flanges, for a sloped connection. A preferred RBS configuration where the center of the RBS is perpendicular to the longitudinal axis of the beam, not parallel to the column as was used in the test specimens, was proposed.
    publisherAmerican Society of Civil Engineers
    titleEvaluation of Sloped RBS Moment Connections
    typeJournal Paper
    journal volume142
    journal issue6
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0001459
    page04016013
    treeJournal of Structural Engineering:;2016:;Volume ( 142 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian