    Effects of Masonry Infill Wall on the Performance of RC Frames to Resist Progressive Collapse

    Source: Journal of Structural Engineering:;2017:;Volume ( 143 ):;issue: 009
    Author:
    Kai Qian
    ,
    Bing Li
    DOI: 10.1061/(ASCE)ST.1943-541X.0001860
    Publisher: American Society of Civil Engineers
    Abstract: Masonry-infilled (MI) panels, which serve as partitions in buildings, are normally considered as architectural elements. Their weights are considered in progressive collapse analysis, but the resistance of the walls is normally ignored in design guidelines. Simple structural analysis predicts that the infill walls, which are commonly equivalent to compressive struts, increase not only the lateral load resistance but also the vertical load resistance of the reinforced concrete (RC) frames. Because extra vertical resistance might reduce the risk of failure, it is necessary to quantify the effects of MI walls on the load resisting capacity of RC frames to mitigate progressive collapse. However, few studies, especially experimental studies, have been carried out on this topic. Thus, six multistory by multibay RC subframes were designed and tested, subjected to push-down loading regimes. The six subframes were categorized into two groups: (1) bare frames without MI walls and (2) infilled frames with MI walls. The failure modes, load-displacement curves, deformation shapes, and strains of the specimens are measured and compared. The effects of the MI wall on the load resisting capacity, initial stiffness, and load resisting mechanisms of RC frames to resist progressive collapse were also evaluated and discussed. The experimental and analytical results indicated that ignoring the effects of MI walls in progressive collapse design may result in substantial inaccuracy in predicting the stiffness, strength, and failure modes of infilled frames to resist progressive collapse. Infill walls with low height/span ratio may fail in splitting of the equivalent compressive struts prior to crushing.
    • Download: (3.165Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Effects of Masonry Infill Wall on the Performance of RC Frames to Resist Progressive Collapse

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4242555
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorKai Qian
    contributor authorBing Li
    date accessioned2017-12-16T09:24:21Z
    date available2017-12-16T09:24:21Z
    date issued2017
    identifier other%28ASCE%29ST.1943-541X.0001860.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4242555
    description abstractMasonry-infilled (MI) panels, which serve as partitions in buildings, are normally considered as architectural elements. Their weights are considered in progressive collapse analysis, but the resistance of the walls is normally ignored in design guidelines. Simple structural analysis predicts that the infill walls, which are commonly equivalent to compressive struts, increase not only the lateral load resistance but also the vertical load resistance of the reinforced concrete (RC) frames. Because extra vertical resistance might reduce the risk of failure, it is necessary to quantify the effects of MI walls on the load resisting capacity of RC frames to mitigate progressive collapse. However, few studies, especially experimental studies, have been carried out on this topic. Thus, six multistory by multibay RC subframes were designed and tested, subjected to push-down loading regimes. The six subframes were categorized into two groups: (1) bare frames without MI walls and (2) infilled frames with MI walls. The failure modes, load-displacement curves, deformation shapes, and strains of the specimens are measured and compared. The effects of the MI wall on the load resisting capacity, initial stiffness, and load resisting mechanisms of RC frames to resist progressive collapse were also evaluated and discussed. The experimental and analytical results indicated that ignoring the effects of MI walls in progressive collapse design may result in substantial inaccuracy in predicting the stiffness, strength, and failure modes of infilled frames to resist progressive collapse. Infill walls with low height/span ratio may fail in splitting of the equivalent compressive struts prior to crushing.
    publisherAmerican Society of Civil Engineers
    titleEffects of Masonry Infill Wall on the Performance of RC Frames to Resist Progressive Collapse
    typeJournal Paper
    journal volume143
    journal issue9
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0001860
    treeJournal of Structural Engineering:;2017:;Volume ( 143 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian