    Evaluation and Load Testing of Posttensioned Concrete Structure Exhibiting Distress

    Source: Journal of Performance of Constructed Facilities:;2016:;Volume ( 030 ):;issue: 001
    Author:
    Ufuk Dilek
    ,
    Engin Murat Reis
    DOI: 10.1061/(ASCE)CF.1943-5509.0000695
    Publisher: American Society of Civil Engineers
    Abstract: This article discusses the evaluation of a posttensioned concrete structure exhibiting cracking using nondestructive evaluation, laboratory testing of concrete samples, and subsequent in situ load testing. During a field survey, it was identified that the posttensioned beams exhibited visually apparent deflections. An engineering evaluation was initiated to identify the cause of this type of cracking in the posttensioned structural system. Following a field survey and document review, an analysis was initiated for the estimation of potential posttension losses and analytical expected deflections for the purposes of comparing it to measured deflections in the field. After the analytical phase, an in situ, nondestructive evaluation phase and a subsequent material testing phase were initiated. The in situ evaluation of the structure involved nondestructive testing of concrete slabs and beams using ground-penetrating radar (GPR) to locate tendons. Cores were removed, and compressive strength testing and petrographic analysis of the cores were performed in the laboratory. Based on the review of the findings of the engineering analysis, nondestructive evaluation, and laboratory testing, the concrete beams and slabs were load-tested in accordance with ACI 318, Chapter 20. The load test served to verify that the structure could safely sustain the service load requirements of the building code. This paper should be of value to consulting engineers engaged in condition assessment of posttensioned structures exhibiting distress, in terms of the test methods used and the methodology used in developing various aspects of the load-testing program.
    • Download: (33.06Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Evaluation and Load Testing of Posttensioned Concrete Structure Exhibiting Distress

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4241573
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorUfuk Dilek
    contributor authorEngin Murat Reis
    date accessioned2017-12-16T09:20:18Z
    date available2017-12-16T09:20:18Z
    date issued2016
    identifier other%28ASCE%29CF.1943-5509.0000695.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4241573
    description abstractThis article discusses the evaluation of a posttensioned concrete structure exhibiting cracking using nondestructive evaluation, laboratory testing of concrete samples, and subsequent in situ load testing. During a field survey, it was identified that the posttensioned beams exhibited visually apparent deflections. An engineering evaluation was initiated to identify the cause of this type of cracking in the posttensioned structural system. Following a field survey and document review, an analysis was initiated for the estimation of potential posttension losses and analytical expected deflections for the purposes of comparing it to measured deflections in the field. After the analytical phase, an in situ, nondestructive evaluation phase and a subsequent material testing phase were initiated. The in situ evaluation of the structure involved nondestructive testing of concrete slabs and beams using ground-penetrating radar (GPR) to locate tendons. Cores were removed, and compressive strength testing and petrographic analysis of the cores were performed in the laboratory. Based on the review of the findings of the engineering analysis, nondestructive evaluation, and laboratory testing, the concrete beams and slabs were load-tested in accordance with ACI 318, Chapter 20. The load test served to verify that the structure could safely sustain the service load requirements of the building code. This paper should be of value to consulting engineers engaged in condition assessment of posttensioned structures exhibiting distress, in terms of the test methods used and the methodology used in developing various aspects of the load-testing program.
    publisherAmerican Society of Civil Engineers
    titleEvaluation and Load Testing of Posttensioned Concrete Structure Exhibiting Distress
    typeJournal Paper
    journal volume30
    journal issue1
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)CF.1943-5509.0000695
    treeJournal of Performance of Constructed Facilities:;2016:;Volume ( 030 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian