contributor author | Rafal Anay | |
contributor author | Tamara M. Cortez | |
contributor author | David V. Jáuregui | |
contributor author | Mohamed K. ElBatanouny | |
contributor author | Paul Ziehl | |
date accessioned | 2017-12-16T09:19:56Z | |
date available | 2017-12-16T09:19:56Z | |
date issued | 2016 | |
identifier other | %28ASCE%29CF.1943-5509.0000810.pdf | |
identifier uri | http://138.201.223.254:8080/yetl1/handle/yetl/4241538 | |
description abstract | Acoustic emission was used in this study to assess the condition of a simple-span, prestressed concrete bridge located in southern New Mexico during a proof test. The 40-year-old bridge is county owned and no design plans were available. Acoustic emission (AE) data were collected under several loading conditions from two groups of sensors placed near the support and midspan of an interior double-tee beam. Strain measurements were also taken at midspan and used to direct the test and determine the maximum loading. AE data analysis methods were applied to evaluate the response of the structure under increasing loads and to develop crack maps. Analysis of the AE data showed signs of internal beam microcrack development near the supports (shear region) as well as in the midspan (moment region). The AE data indicated that damage in the form of crack growth was more prevalent in the region near the supports. | |
publisher | American Society of Civil Engineers | |
title | On-Site Acoustic-Emission Monitoring for Assessment of a Prestressed Concrete Double-Tee-Beam Bridge without Plans | |
type | Journal Paper | |
journal volume | 30 | |
journal issue | 4 | |
journal title | Journal of Performance of Constructed Facilities | |
identifier doi | 10.1061/(ASCE)CF.1943-5509.0000810 | |
tree | Journal of Performance of Constructed Facilities:;2016:;Volume ( 030 ):;issue: 004 | |
contenttype | Fulltext | |