    Forensic Diagnosis of a Leaking Accident during Excavation

    Source: Journal of Performance of Constructed Facilities:;2017:;Volume ( 031 ):;issue: 005
    Author:
    Yong Tan
    ,
    Ye Lu
    DOI: 10.1061/(ASCE)CF.1943-5509.0001058
    Publisher: American Society of Civil Engineers
    Abstract: Construction of a subway station in Shanghai called for a 31.4–33.1–m-deep excavation, which extended through upper impermeable clayey strata into underlying erodible silt and sand aquifer layers. When the north section of this pit nearly bottomed out on July 23, 2013, a sudden outburst of groundwater took place and the pit base was flooded quickly. In the subsequent two days, the adjacent ground and building successively underwent 30–42-mm settlements in a plunging manner. To prevent aggravation of the situation, a contingency plan was initiated quickly in an attempt to seal off the water flow path. By constructing mixed-in-place and jet-grouting piles respectively along the outer and inner perimeters of the diaphragm wall where leakage occurred, flow channels were successfully blocked. Despite this, the building adjacent to the outburst of groundwater suffered long-term postexcavation settlement. Forensic diagnoses show that this through-wall leaking accident was related to two major factors: (1) ignorance of minor leakages emerging two weeks before without adopting any remedial measure; and (2) a flawed slab connector embedded in the confined aquifer layer. Based on visual inspection and retrospective analysis of field monitoring data, the possible leakage flow path and associated ground subsidence zone were mapped and a settlement history of the affected building was reconstructed. Both contractual and technical lessons learned from this accident will be useful for professionals to mitigate or prevent future incidence of through-wall leakage during excavation.
    • Download: (4.265Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Forensic Diagnosis of a Leaking Accident during Excavation

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4241405
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorYong Tan
    contributor authorYe Lu
    date accessioned2017-12-16T09:19:11Z
    date available2017-12-16T09:19:11Z
    date issued2017
    identifier other%28ASCE%29CF.1943-5509.0001058.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4241405
    description abstractConstruction of a subway station in Shanghai called for a 31.4–33.1–m-deep excavation, which extended through upper impermeable clayey strata into underlying erodible silt and sand aquifer layers. When the north section of this pit nearly bottomed out on July 23, 2013, a sudden outburst of groundwater took place and the pit base was flooded quickly. In the subsequent two days, the adjacent ground and building successively underwent 30–42-mm settlements in a plunging manner. To prevent aggravation of the situation, a contingency plan was initiated quickly in an attempt to seal off the water flow path. By constructing mixed-in-place and jet-grouting piles respectively along the outer and inner perimeters of the diaphragm wall where leakage occurred, flow channels were successfully blocked. Despite this, the building adjacent to the outburst of groundwater suffered long-term postexcavation settlement. Forensic diagnoses show that this through-wall leaking accident was related to two major factors: (1) ignorance of minor leakages emerging two weeks before without adopting any remedial measure; and (2) a flawed slab connector embedded in the confined aquifer layer. Based on visual inspection and retrospective analysis of field monitoring data, the possible leakage flow path and associated ground subsidence zone were mapped and a settlement history of the affected building was reconstructed. Both contractual and technical lessons learned from this accident will be useful for professionals to mitigate or prevent future incidence of through-wall leakage during excavation.
    publisherAmerican Society of Civil Engineers
    titleForensic Diagnosis of a Leaking Accident during Excavation
    typeJournal Paper
    journal volume31
    journal issue5
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)CF.1943-5509.0001058
    treeJournal of Performance of Constructed Facilities:;2017:;Volume ( 031 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace