Show simple item record

contributor authorBruse, Jan L.
contributor authorGiusti, Giuliano
contributor authorBaker, Catriona
contributor authorCervi, Elena
contributor authorHsia, Tain-Yen
contributor authorTaylor, Andrew M.
contributor authorSchievano, Silvia
date accessioned2017-11-25T07:18:31Z
date available2017-11-25T07:18:31Z
date copyright2017/3/5
date issued2017
identifier issn1932-6181
identifier othermed_011_02_021011.pdf
identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4235218
description abstractPatients born with a single functional ventricle typically undergo three-staged surgical palliation in the first years of life, with the last stage realizing a cross-like total cavopulmonary connection (TCPC) of superior and inferior vena cavas (SVC and IVC) with both left and right pulmonary arteries (LPA and RPA), allowing all deoxygenated blood to flow passively back to the lungs (Fontan circulation). Even though within the past decades more patients survive into adulthood, the connection comes at the prize of deficiencies such as chronic systemic venous hypertension and low cardiac output (CO), which ultimately may lead to Fontan failure. Many studies have suggested that the TCPC’s inherent insufficiencies might be addressed by adding a cavopulmonary assist device (CPAD) to provide the necessary pressure boost. While many device concepts are being explored, few take into account the complex cardiac anatomy typically associated with TCPCs. In this study, we focus on the extra cardiac conduit (ECC) vascular graft connecting IVC and pulmonary arteries (PAs) as one possible landing zone for a CPAD and describe its geometric variability in a cohort of 18 patients that had their TCPC realized with a 20 mm vascular graft. We report traditional morphometric parameters and apply statistical shape modeling (SSM) to determine the main contributors of graft shape variability. Such information may prove useful when designing CPADs that are adapted to the challenging anatomical boundaries in Fontan patients. We further compute the anatomical mean 3D graft shape (template graft) as a representative of key shape features of our cohort and prove this template graft to be a significantly better approximation of population and individual patient’s hemodynamics than a commonly used simplified tube geometry. We therefore conclude that statistical shape modeling results can provide better models of geometric and hemodynamic boundary conditions associated with complex cardiac anatomy, which in turn may impact on improved cardiac device development.
publisherThe American Society of Mechanical Engineers (ASME)
titleStatistical Shape Modeling for Cavopulmonary Assist Device Development: Variability of Vascular Graft Geometry and Implications for Hemodynamics
typeJournal Paper
journal volume11
journal issue2
journal titleJournal of Medical Devices
identifier doi10.1115/1.4035865
journal fristpage21011
journal lastpage021011-11
treeJournal of Medical Devices:;2017:;volume( 011 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record