Show simple item record

contributor authorWang, Liang
contributor authorZhu, Jian
contributor authorSamady, Habib
contributor authorMonoly, David
contributor authorZheng, Jie
contributor authorGuo, Xiaoya
contributor authorMaehara, Akiko
contributor authorYang, Chun
contributor authorMa, Genshan
contributor authorMintz, Gary S.
contributor authorTang, Dalin
date accessioned2017-11-25T07:18:21Z
date available2017-11-25T07:18:21Z
date copyright2016/4/11
date issued2017
identifier issn0148-0731
identifier otherbio_139_01_014501.pdf
identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4235141
description abstractAccurate stress and strain calculations are important for plaque progression and vulnerability assessment. Models based on in vivo data often need to form geometries with zero-stress/strain conditions. The goal of this paper is to use IVUS-based near-idealized geometries and introduce a three-step model construction process to include residual stress, axial shrinkage, and circumferential shrinkage and investigate their impacts on stress and strain calculations. In Vivo intravascular ultrasound (IVUS) data of human coronary were acquired for model construction. In Vivo IVUS movie data were acquired and used to determine patient-specific material parameter values. A three-step modeling procedure was used to make our model: (a) wrap the zero-stress vessel sector to obtain the residual stress; (b) stretch the vessel axially to its length in vivo; and (c) pressurize the vessel to recover its in vivo geometry. Eight models were constructed for our investigation. Wrapping led to reduced lumen and cap stress and increased out boundary stress. The model with axial stretch, circumferential shrink, but no wrapping overestimated lumen and cap stress by 182% and 448%, respectively. The model with wrapping, circumferential shrink, but no axial stretch predicted average lumen stress and cap stress as 0.76 kPa and −15 kPa. The same model with 10% axial stretch had 42.53 kPa lumen stress and 29.0 kPa cap stress, respectively. Skipping circumferential shrinkage leads to overexpansion of the vessel and incorrect stress/strain calculations. Vessel stiffness increase (100%) leads to 75% lumen stress increase and 102% cap stress increase.
publisherThe American Society of Mechanical Engineers (ASME)
titleEffects of Residual Stress, Axial Stretch, and Circumferential Shrinkage on Coronary Plaque Stress and Strain Calculations: A Modeling Study Using IVUS-Based Near-Idealized Geometries
typeJournal Paper
journal volume139
journal issue1
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4034867
journal fristpage14501
journal lastpage014501-11
treeJournal of Biomechanical Engineering:;2017:;volume( 139 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record