description abstract | The design of an improved sampler for the automatic collection of air samples during atmospheric halogenated tracer experiments is described. In this approach, each sample is collected in a small volume (20 to 150 ml) syringe using a rack and pinion drive powered by a precision stepper motor. The sampling rate is controlled via a quartz crystal oscillator and clock to yield averaging periods from 2 to 120 minutes per syringe, and as many as twelve syringe samples can be collected sequentially. Start-up of the sampler is pre-selected using a digital clock and calendar. The sampler is battery-powered, portable and designed for rugged field use. Sample return rates as high as 97% have been achieved in a number of large tracer field programs. Typical results from several of these investigations are also presented. | |
publisher | American Meteorological Society | |
title | An Automated Sequential Syringe Sampler for Atmospheric Tracer Studies | |
type | Journal Paper | |
journal volume | 1 | |
journal issue | 4 | |
journal title | Journal of Atmospheric and Oceanic Technology | |
identifier doi | 10.1175/1520-0426(1984)001<0372:AASSSF>2.0.CO;2 | |
journal fristpage | 372 | |
journal lastpage | 378 | |
tree | Journal of Atmospheric and Oceanic Technology:;1984:;volume( 001 ):;issue: 004 | |
contenttype | Fulltext | |