| contributor author | Stevens, J. L. | |
| contributor author | Wright, J. L. | |
| date accessioned | 2017-06-09T17:39:03Z | |
| date available | 2017-06-09T17:39:03Z | |
| date copyright | 1977/05/01 | |
| date issued | 1977 | |
| identifier issn | 0021-8952 | |
| identifier other | ams-9274.pdf | |
| identifier uri | http://onlinelibrary.yabesh.ir/handle/yetl/4232744 | |
| description abstract | A recirculating purging system for soft dome net radiometers was developed to prevent internal fogging and reduce maintenance during cool and wet weather. An airflow of 3?5 mm3 s?1 was sufficient to keep the domes inflated and clear of condensate without introducing signal errors. The desiccant needs to be changed only two to three times a year. | |
| publisher | American Meteorological Society | |
| title | Recirculating Purging System for Hemispherical Net Radiometers | |
| type | Journal Paper | |
| journal volume | 16 | |
| journal issue | 5 | |
| journal title | Journal of Applied Meteorology | |
| identifier doi | 10.1175/1520-0450(1977)016<0565:RPSFHN>2.0.CO;2 | |
| journal fristpage | 565 | |
| journal lastpage | 566 | |
| tree | Journal of Applied Meteorology:;1977:;volume( 016 ):;issue: 005 | |
| contenttype | Fulltext | |