    Recirculating Purging System for Hemispherical Net Radiometers

    Source: Journal of Applied Meteorology:;1977:;volume( 016 ):;issue: 005::page 565
    Author:
    Stevens, J. L.
    ,
    Wright, J. L.
    DOI: 10.1175/1520-0450(1977)016<0565:RPSFHN>2.0.CO;2
    Publisher: American Meteorological Society
    Abstract: A recirculating purging system for soft dome net radiometers was developed to prevent internal fogging and reduce maintenance during cool and wet weather. An airflow of 3?5 mm3 s?1 was sufficient to keep the domes inflated and clear of condensate without introducing signal errors. The desiccant needs to be changed only two to three times a year.
    • Download: (133.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Recirculating Purging System for Hemispherical Net Radiometers

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4232744
    Collections
    • Journal of Applied Meteorology

    Show full item record

    contributor authorStevens, J. L.
    contributor authorWright, J. L.
    date accessioned2017-06-09T17:39:03Z
    date available2017-06-09T17:39:03Z
    date copyright1977/05/01
    date issued1977
    identifier issn0021-8952
    identifier otherams-9274.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4232744
    description abstractA recirculating purging system for soft dome net radiometers was developed to prevent internal fogging and reduce maintenance during cool and wet weather. An airflow of 3?5 mm3 s?1 was sufficient to keep the domes inflated and clear of condensate without introducing signal errors. The desiccant needs to be changed only two to three times a year.
    publisherAmerican Meteorological Society
    titleRecirculating Purging System for Hemispherical Net Radiometers
    typeJournal Paper
    journal volume16
    journal issue5
    journal titleJournal of Applied Meteorology
    identifier doi10.1175/1520-0450(1977)016<0565:RPSFHN>2.0.CO;2
    journal fristpage565
    journal lastpage566
    treeJournal of Applied Meteorology:;1977:;volume( 016 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian