YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • AMS
    • Monthly Weather Review
    • View Item
    •   YE&T Library
    • AMS
    • Monthly Weather Review
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Sensitivity of Dryline Convection Forecasts to Upstream Forecast Errors for Two Weakly Forced MPEX Cases

    Source: Monthly Weather Review:;2017:;volume( 145 ):;issue: 005::page 1831
    Author:
    Torn, Ryan D.
    ,
    Romine, Glen S.
    ,
    Galarneau, Thomas J.
    DOI: 10.1175/MWR-D-16-0457.1
    Publisher: American Meteorological Society
    Abstract: he sensitivity of convective forecasts along the Texas dryline to upstream forecast fields at earlier lead times is evaluated for two consecutive days (27?28 May) characterized by no clear synoptic forcing for convection initiation (CI) during the 2013 Mesoscale Predictability Experiment (MPEX) by applying the ensemble-based sensitivity technique to convection-allowing WRF ensemble forecasts. For both cases, the members with stronger convection are characterized by higher water vapor just above the top of the boundary layer, which is associated with lower convective inhibition (CIN) at the time of CI. Forecast convection is sensitive to the lower-tropospheric water vapor and zonal wind at earlier lead times farther south along the dryline, such that increasing the water vapor and/or making the wind more easterly is associated with more convection. For 28 May, the water vapor along the dryline is also sensitive to the convection that occurs around 0600 UTC, which leads to cold pool?induced surface divergence that subsequently shifts the dryline north or south. Ensemble members that correctly have decreased convection in the Texas Panhandle on 28 May have more accurate forecasts of water vapor and meridional wind with respect to dropwindsondes in the sensitive region 9 h prior to CI compared to members with more extensive convection. Reducing the 0-h water vapor within the sensitive region can suppress convection in members with extensive convection; however, increasing the 0-h water vapor does not lead to more convection in members without convection.
    • Download: (6.903Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Sensitivity of Dryline Convection Forecasts to Upstream Forecast Errors for Two Weakly Forced MPEX Cases

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4231131
    Collections
    • Monthly Weather Review

    Show full item record

    contributor authorTorn, Ryan D.
    contributor authorRomine, Glen S.
    contributor authorGalarneau, Thomas J.
    date accessioned2017-06-09T17:34:42Z
    date available2017-06-09T17:34:42Z
    date copyright2017/05/01
    date issued2017
    identifier issn0027-0644
    identifier otherams-87460.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4231131
    description abstracthe sensitivity of convective forecasts along the Texas dryline to upstream forecast fields at earlier lead times is evaluated for two consecutive days (27?28 May) characterized by no clear synoptic forcing for convection initiation (CI) during the 2013 Mesoscale Predictability Experiment (MPEX) by applying the ensemble-based sensitivity technique to convection-allowing WRF ensemble forecasts. For both cases, the members with stronger convection are characterized by higher water vapor just above the top of the boundary layer, which is associated with lower convective inhibition (CIN) at the time of CI. Forecast convection is sensitive to the lower-tropospheric water vapor and zonal wind at earlier lead times farther south along the dryline, such that increasing the water vapor and/or making the wind more easterly is associated with more convection. For 28 May, the water vapor along the dryline is also sensitive to the convection that occurs around 0600 UTC, which leads to cold pool?induced surface divergence that subsequently shifts the dryline north or south. Ensemble members that correctly have decreased convection in the Texas Panhandle on 28 May have more accurate forecasts of water vapor and meridional wind with respect to dropwindsondes in the sensitive region 9 h prior to CI compared to members with more extensive convection. Reducing the 0-h water vapor within the sensitive region can suppress convection in members with extensive convection; however, increasing the 0-h water vapor does not lead to more convection in members without convection.
    publisherAmerican Meteorological Society
    titleSensitivity of Dryline Convection Forecasts to Upstream Forecast Errors for Two Weakly Forced MPEX Cases
    typeJournal Paper
    journal volume145
    journal issue5
    journal titleMonthly Weather Review
    identifier doi10.1175/MWR-D-16-0457.1
    journal fristpage1831
    journal lastpage1852
    treeMonthly Weather Review:;2017:;volume( 145 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian