YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • AMS
    • Monthly Weather Review
    • View Item
    •   YE&T Library
    • AMS
    • Monthly Weather Review
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    A 10-Year Study on the Characteristics of Thunderstorms in Belgium Based on Cloud-to-Ground Lightning Data

    Source: Monthly Weather Review:;2014:;volume( 142 ):;issue: 012::page 4839
    Author:
    Poelman, Dieter R.
    DOI: 10.1175/MWR-D-14-00202.1
    Publisher: American Meteorological Society
    Abstract: emporal and spatial distributions of cloud-to-ground (CG) lightning in Belgium are analyzed. Based on data from the European Cooperation for Lightning Detection (EUCLID) network, spanning a period of 10 years between 2004 and 2013, mean CG flash densities vary between 0.3 km?2 yr?1 in the west up to 2.4 km?2 yr?1 toward the east of Belgium, with an average flash density of 0.7 km?2 yr?1. The same behavior is found in terms of thunderstorm days and hours, where in the east most of the activity is observed, with a drop-off toward the coast. The majority of lightning activity takes place in the summer months between May and August, accounting for nearly 90% of the total activity. Furthermore, the thunderstorm season reaches its highest activity in July in terms of CG detections, while the diurnal cycle peaks between 1500 and 1600 UTC. A correlation is found between the estimated peak currents and altitude, with on average higher absolute peak currents at lower elevations and vice versa. In addition, a cell tracking algorithm is applied to the data to monitor the behavior of the individual cells. It is found that the lightning cells travel at an average speed of about 25 km h?1, with a preferred northeasterly direction of movement. At last, CG flash rates are strongly related to the cell area.
    • Download: (1.467Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A 10-Year Study on the Characteristics of Thunderstorms in Belgium Based on Cloud-to-Ground Lightning Data

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4230548
    Collections
    • Monthly Weather Review

    Show full item record

    contributor authorPoelman, Dieter R.
    date accessioned2017-06-09T17:32:23Z
    date available2017-06-09T17:32:23Z
    date copyright2014/12/01
    date issued2014
    identifier issn0027-0644
    identifier otherams-86935.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4230548
    description abstractemporal and spatial distributions of cloud-to-ground (CG) lightning in Belgium are analyzed. Based on data from the European Cooperation for Lightning Detection (EUCLID) network, spanning a period of 10 years between 2004 and 2013, mean CG flash densities vary between 0.3 km?2 yr?1 in the west up to 2.4 km?2 yr?1 toward the east of Belgium, with an average flash density of 0.7 km?2 yr?1. The same behavior is found in terms of thunderstorm days and hours, where in the east most of the activity is observed, with a drop-off toward the coast. The majority of lightning activity takes place in the summer months between May and August, accounting for nearly 90% of the total activity. Furthermore, the thunderstorm season reaches its highest activity in July in terms of CG detections, while the diurnal cycle peaks between 1500 and 1600 UTC. A correlation is found between the estimated peak currents and altitude, with on average higher absolute peak currents at lower elevations and vice versa. In addition, a cell tracking algorithm is applied to the data to monitor the behavior of the individual cells. It is found that the lightning cells travel at an average speed of about 25 km h?1, with a preferred northeasterly direction of movement. At last, CG flash rates are strongly related to the cell area.
    publisherAmerican Meteorological Society
    titleA 10-Year Study on the Characteristics of Thunderstorms in Belgium Based on Cloud-to-Ground Lightning Data
    typeJournal Paper
    journal volume142
    journal issue12
    journal titleMonthly Weather Review
    identifier doi10.1175/MWR-D-14-00202.1
    journal fristpage4839
    journal lastpage4849
    treeMonthly Weather Review:;2014:;volume( 142 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian