    A Two-Stage Quality Control Method for 2-m Temperature Observations Using Biweight Means and a Progressive EOF Analysis

    Source: Monthly Weather Review:;2012:;volume( 141 ):;issue: 002::page 798
    Author:
    Xu, Zhifang
    ,
    Wang, Yi
    ,
    Fan, Guangzhou
    DOI: 10.1175/MWR-D-11-00308.1
    Publisher: American Meteorological Society
    Abstract: he relatively smooth terrain embedded in the numerical model creates an elevation difference against the actual terrain, which in turn makes the quality control of 2-m temperature difficult when forecast or analysis fields are utilized in the process. In this paper, a two-stage quality control method is proposed to address the quality control of 2-m temperature, using biweight means and a progressive EOF analysis. The study is made to improve the quality control of the observed 2-m temperature collected by China and its neighboring areas, based on the 6-h T639 analysis from December 2009 to February 2010. Results show that the proposed two-stage quality control method can secure the needed quality control better, compared with a regular EOF quality control process. The new method is, in particular, able to remove the data that are dotted with consecutive errors but showing small fluctuations. Meanwhile, compared with the lapse rate of temperature method, the biweight mean method is able to remove the systematic bias generated by the model. It turns out that such methods make the distributions of observation increments (the difference between observation and background) more Gaussian-like, which ensures the data quality after the quality control.
    • Download: (1.697Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Two-Stage Quality Control Method for 2-m Temperature Observations Using Biweight Means and a Progressive EOF Analysis

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4229818
    Collections
    • Monthly Weather Review

    Show full item record

    contributor authorXu, Zhifang
    contributor authorWang, Yi
    contributor authorFan, Guangzhou
    date accessioned2017-06-09T17:29:51Z
    date available2017-06-09T17:29:51Z
    date copyright2013/02/01
    date issued2012
    identifier issn0027-0644
    identifier otherams-86278.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4229818
    description abstracthe relatively smooth terrain embedded in the numerical model creates an elevation difference against the actual terrain, which in turn makes the quality control of 2-m temperature difficult when forecast or analysis fields are utilized in the process. In this paper, a two-stage quality control method is proposed to address the quality control of 2-m temperature, using biweight means and a progressive EOF analysis. The study is made to improve the quality control of the observed 2-m temperature collected by China and its neighboring areas, based on the 6-h T639 analysis from December 2009 to February 2010. Results show that the proposed two-stage quality control method can secure the needed quality control better, compared with a regular EOF quality control process. The new method is, in particular, able to remove the data that are dotted with consecutive errors but showing small fluctuations. Meanwhile, compared with the lapse rate of temperature method, the biweight mean method is able to remove the systematic bias generated by the model. It turns out that such methods make the distributions of observation increments (the difference between observation and background) more Gaussian-like, which ensures the data quality after the quality control.
    publisherAmerican Meteorological Society
    titleA Two-Stage Quality Control Method for 2-m Temperature Observations Using Biweight Means and a Progressive EOF Analysis
    typeJournal Paper
    journal volume141
    journal issue2
    journal titleMonthly Weather Review
    identifier doi10.1175/MWR-D-11-00308.1
    journal fristpage798
    journal lastpage808
    treeMonthly Weather Review:;2012:;volume( 141 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian