    Modeling the Flash Rate of Thunderstorms. Part II: Implementation

    Source: Monthly Weather Review:;2011:;volume( 139 ):;issue: 010::page 3112
    Author:
    Dahl, Johannes M. L.
    ,
    Höller, Hartmut
    ,
    Schumann, Ulrich
    DOI: 10.1175/MWR-D-10-05032.1
    Publisher: American Meteorological Society
    Abstract: n Part I of this two-part paper a new method of predicting the total lightning flash rate in thunderstorms was introduced. In this paper, the implementation of this method into the convection-permitting Consortium for Small Scale Modeling (COSMO) model is presented.The new approach is based on a simple theoretical model that consists of a dipole charge structure, which is maintained by a generator current and discharged by lightning and, to a small extent, by a leakage current. This approach yields a set of four predictor variables, which are not amenable to direct observations and consequently need to be parameterized (Part I).Using an algorithm that identifies thunderstorm cells and their properties, this approach is applied to determine the flash frequency of every thunderstorm cell in the model domain. With this information, the number of flashes that are accumulated by each cell and during the interval between the activation of the lightning scheme can be calculated.These flashes are then randomly distributed in time and beneath each cell. The output contains the longitude, the latitude, and the time of occurrence of each simulated discharge.Simulations of real-world scenarios are presented, which are compared to measurements with the lightning detection network, LINET. These comparisons are done on the cloud scale as well as in a mesoscale region composing southern Germany (two cases each). The flash rates of individual cumulonimbus clouds at the extreme ends of the intensity spectrum are realistically simulated. The simulated overall lightning activity over southern Germany is dominated by spatiotemporal displacements of the modeled convective clouds, although the scheme generally reproduces realistic patterns such as coherent lightning swaths.
    • Download: (5.011Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Modeling the Flash Rate of Thunderstorms. Part II: Implementation

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4229574
    Collections
    • Monthly Weather Review

    Show full item record

    contributor authorDahl, Johannes M. L.
    contributor authorHöller, Hartmut
    contributor authorSchumann, Ulrich
    date accessioned2017-06-09T17:28:57Z
    date available2017-06-09T17:28:57Z
    date copyright2011/10/01
    date issued2011
    identifier issn0027-0644
    identifier otherams-86058.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4229574
    description abstractn Part I of this two-part paper a new method of predicting the total lightning flash rate in thunderstorms was introduced. In this paper, the implementation of this method into the convection-permitting Consortium for Small Scale Modeling (COSMO) model is presented.The new approach is based on a simple theoretical model that consists of a dipole charge structure, which is maintained by a generator current and discharged by lightning and, to a small extent, by a leakage current. This approach yields a set of four predictor variables, which are not amenable to direct observations and consequently need to be parameterized (Part I).Using an algorithm that identifies thunderstorm cells and their properties, this approach is applied to determine the flash frequency of every thunderstorm cell in the model domain. With this information, the number of flashes that are accumulated by each cell and during the interval between the activation of the lightning scheme can be calculated.These flashes are then randomly distributed in time and beneath each cell. The output contains the longitude, the latitude, and the time of occurrence of each simulated discharge.Simulations of real-world scenarios are presented, which are compared to measurements with the lightning detection network, LINET. These comparisons are done on the cloud scale as well as in a mesoscale region composing southern Germany (two cases each). The flash rates of individual cumulonimbus clouds at the extreme ends of the intensity spectrum are realistically simulated. The simulated overall lightning activity over southern Germany is dominated by spatiotemporal displacements of the modeled convective clouds, although the scheme generally reproduces realistic patterns such as coherent lightning swaths.
    publisherAmerican Meteorological Society
    titleModeling the Flash Rate of Thunderstorms. Part II: Implementation
    typeJournal Paper
    journal volume139
    journal issue10
    journal titleMonthly Weather Review
    identifier doi10.1175/MWR-D-10-05032.1
    journal fristpage3112
    journal lastpage3124
    treeMonthly Weather Review:;2011:;volume( 139 ):;issue: 010
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian