YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • AMS
    • Monthly Weather Review
    • View Item
    •   YE&T Library
    • AMS
    • Monthly Weather Review
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Data Quality Control Based on Self-Consistency

    Source: Monthly Weather Review:;2011:;volume( 139 ):;issue: 012::page 3974
    Author:
    Steinacker, Reinhold
    ,
    Mayer, Dieter
    ,
    Steiner, Andrea
    DOI: 10.1175/MWR-D-10-05024.1
    Publisher: American Meteorological Society
    Abstract: onducting meteorological measurements, one is always confronted with a wide variety of different types of errors and with the decision of how to correct data for further use, if necessary. The selection of an adequate quality control (QC) procedure out of a wide range of methodologies depends on the properties of the observed parameter such as spatial or temporal consistency. But the intended data application (e.g., model-independent data analysis) or the availability of prior knowledge also has to be taken into account. The herein-presented self-consistent and model-independent QC process makes use of the spatial and temporal consistency of meteorological parameters. It is applicable to measurements featuring a high degree of autocorrelation with regard to the resolution of the observational network in space and time. The presented QC procedure can mathematically be expressed as an optimization problem minimizing the curvature of the analyzed field. This results in a matrix equation that can be solved without needing to converge iterations. Based on the resulting deviations and, if applied, on their impacts on the cost function, station values are accepted, corrected, or identified as outliers and hence dismissed. Furthermore, it is pointed out that this method is able to handle complicated station distributions, such as clustered stations or inhomogeneous station densities. This QC method is not only an appropriate tool for case studies but also for model validation and has been proving itself as a preprocessing tool for operational meso- and micrometeorological analyses.
    • Download: (5.167Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Data Quality Control Based on Self-Consistency

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4229568
    Collections
    • Monthly Weather Review

    Show full item record

    contributor authorSteinacker, Reinhold
    contributor authorMayer, Dieter
    contributor authorSteiner, Andrea
    date accessioned2017-06-09T17:28:56Z
    date available2017-06-09T17:28:56Z
    date copyright2011/12/01
    date issued2011
    identifier issn0027-0644
    identifier otherams-86052.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4229568
    description abstractonducting meteorological measurements, one is always confronted with a wide variety of different types of errors and with the decision of how to correct data for further use, if necessary. The selection of an adequate quality control (QC) procedure out of a wide range of methodologies depends on the properties of the observed parameter such as spatial or temporal consistency. But the intended data application (e.g., model-independent data analysis) or the availability of prior knowledge also has to be taken into account. The herein-presented self-consistent and model-independent QC process makes use of the spatial and temporal consistency of meteorological parameters. It is applicable to measurements featuring a high degree of autocorrelation with regard to the resolution of the observational network in space and time. The presented QC procedure can mathematically be expressed as an optimization problem minimizing the curvature of the analyzed field. This results in a matrix equation that can be solved without needing to converge iterations. Based on the resulting deviations and, if applied, on their impacts on the cost function, station values are accepted, corrected, or identified as outliers and hence dismissed. Furthermore, it is pointed out that this method is able to handle complicated station distributions, such as clustered stations or inhomogeneous station densities. This QC method is not only an appropriate tool for case studies but also for model validation and has been proving itself as a preprocessing tool for operational meso- and micrometeorological analyses.
    publisherAmerican Meteorological Society
    titleData Quality Control Based on Self-Consistency
    typeJournal Paper
    journal volume139
    journal issue12
    journal titleMonthly Weather Review
    identifier doi10.1175/MWR-D-10-05024.1
    journal fristpage3974
    journal lastpage3991
    treeMonthly Weather Review:;2011:;volume( 139 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian