    Evaluation of a Bowen Ratio Measurement System over Forest and Clear-Cut Sites at Petawawa, Ontario

    Source: Journal of Atmospheric and Oceanic Technology:;1984:;volume( 001 ):;issue: 003::page 276
    Author:
    McCaughey, J. H.
    ,
    Brintnell, D. M.
    DOI: 10.1175/1520-0426(1984)001<0276:EOABRM>2.0.CO;2
    Publisher: American Meteorological Society
    Abstract: This paper reports on the features of a reversing measurement system for the determination of the Bowen ratio. Ten-junction thermopiles are used to measure wet- and dry-bulb temperature differences, and a single thermocouple gives absolute wet-bulb temperature. The system is totally DC-powered and can be constructed to be portable. The performance of the system was evaluated in an experiment at the Petawawa National Forestry Institute, Chalk River, Ontario. The characteristics of the temperature gradients above a forest and a logged site are reported, along with the corresponding values of the Bowen ratio.
    • Download: (489.5Kb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Evaluation of a Bowen Ratio Measurement System over Forest and Clear-Cut Sites at Petawawa, Ontario

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4229510
    Collections
    • Journal of Atmospheric and Oceanic Technology

    Show full item record

    contributor authorMcCaughey, J. H.
    contributor authorBrintnell, D. M.
    date accessioned2017-06-09T17:28:43Z
    date available2017-06-09T17:28:43Z
    date copyright1984/09/01
    date issued1984
    identifier issn0739-0572
    identifier otherams-86.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4229510
    description abstractThis paper reports on the features of a reversing measurement system for the determination of the Bowen ratio. Ten-junction thermopiles are used to measure wet- and dry-bulb temperature differences, and a single thermocouple gives absolute wet-bulb temperature. The system is totally DC-powered and can be constructed to be portable. The performance of the system was evaluated in an experiment at the Petawawa National Forestry Institute, Chalk River, Ontario. The characteristics of the temperature gradients above a forest and a logged site are reported, along with the corresponding values of the Bowen ratio.
    publisherAmerican Meteorological Society
    titleEvaluation of a Bowen Ratio Measurement System over Forest and Clear-Cut Sites at Petawawa, Ontario
    typeJournal Paper
    journal volume1
    journal issue3
    journal titleJournal of Atmospheric and Oceanic Technology
    identifier doi10.1175/1520-0426(1984)001<0276:EOABRM>2.0.CO;2
    journal fristpage276
    journal lastpage282
    treeJournal of Atmospheric and Oceanic Technology:;1984:;volume( 001 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian