    Calibration and Stability of Oxygen Sensors on Autonomous Floats

    Source: Journal of Atmospheric and Oceanic Technology:;2013:;volume( 030 ):;issue: 008::page 1896
    Author:
    D'Asaro, Eric A.
    ,
    McNeil, Craig
    DOI: 10.1175/JTECH-D-12-00222.1
    Publisher: American Meteorological Society
    Abstract: he calibration accuracy and stability of three Aanderaa 3835 optodes and three Sea-Bird Electronics SBE-43 oxygen sensors were evaluated over four years using in situ and laboratory calibrations. The sensors were mostly in storage, being in the ocean for typically only a few weeks per year and operated for only a few days per year. Both sensors measure partial pressure of oxygen, or equivalently saturation at standard pressure; results are expressed in this variable. It is assumed that sensor drift occurs in the oxygen sensitivity of the sensors, not the temperature compensation; this is well justified for the SBE-43 based on multiple calibrations. Neither sensor had significant long-term drift in output when sampling anoxic water. Sensor output at 100% saturation differed from the factory calibrations by up to ±6% (averaging ?2.3% ± 3%) for the SBE-43 and up to ?12.6% for the optodes. The optode output at 100% saturation is well described by a single decaying exponential with a decay constant of approximately 2 yr and an amplitude of 28%. The mechanism of this drift is unknown but is not primarily due to sensor operation. It may be different from that experienced by sensors continuously deployed in the ocean. Thus, although the optodes in this study did not have a stable calibration, their drift was stable and, once calibrated, allowed optode and SBE-43 pairs mounted on the same autonomous floats to be calibrated to an accuracy of ±0.4% over a 4-yr period.
    • Download: (1.457Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Calibration and Stability of Oxygen Sensors on Autonomous Floats

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4228206
    Collections
    • Journal of Atmospheric and Oceanic Technology

    Show full item record

    contributor authorD'Asaro, Eric A.
    contributor authorMcNeil, Craig
    date accessioned2017-06-09T17:24:59Z
    date available2017-06-09T17:24:59Z
    date copyright2013/08/01
    date issued2013
    identifier issn0739-0572
    identifier otherams-84827.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4228206
    description abstracthe calibration accuracy and stability of three Aanderaa 3835 optodes and three Sea-Bird Electronics SBE-43 oxygen sensors were evaluated over four years using in situ and laboratory calibrations. The sensors were mostly in storage, being in the ocean for typically only a few weeks per year and operated for only a few days per year. Both sensors measure partial pressure of oxygen, or equivalently saturation at standard pressure; results are expressed in this variable. It is assumed that sensor drift occurs in the oxygen sensitivity of the sensors, not the temperature compensation; this is well justified for the SBE-43 based on multiple calibrations. Neither sensor had significant long-term drift in output when sampling anoxic water. Sensor output at 100% saturation differed from the factory calibrations by up to ±6% (averaging ?2.3% ± 3%) for the SBE-43 and up to ?12.6% for the optodes. The optode output at 100% saturation is well described by a single decaying exponential with a decay constant of approximately 2 yr and an amplitude of 28%. The mechanism of this drift is unknown but is not primarily due to sensor operation. It may be different from that experienced by sensors continuously deployed in the ocean. Thus, although the optodes in this study did not have a stable calibration, their drift was stable and, once calibrated, allowed optode and SBE-43 pairs mounted on the same autonomous floats to be calibrated to an accuracy of ±0.4% over a 4-yr period.
    publisherAmerican Meteorological Society
    titleCalibration and Stability of Oxygen Sensors on Autonomous Floats
    typeJournal Paper
    journal volume30
    journal issue8
    journal titleJournal of Atmospheric and Oceanic Technology
    identifier doi10.1175/JTECH-D-12-00222.1
    journal fristpage1896
    journal lastpage1906
    treeJournal of Atmospheric and Oceanic Technology:;2013:;volume( 030 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian