    An Equilibrator System to Measure Dissolved Oxygen and Its Isotopes

    Source: Journal of Atmospheric and Oceanic Technology:;2012:;volume( 030 ):;issue: 002::page 361
    Author:
    Rafelski, Lauren Elmegreen
    ,
    Paplawsky, Bill
    ,
    Keeling, Ralph F.
    DOI: 10.1175/JTECH-D-12-00074.1
    Publisher: American Meteorological Society
    Abstract: n equilibrator is presented that is designed to have a sufficient equilibration time even for insoluble gases, and to minimize artifacts associated with not equilibrating to the total gas tension. A gas tension device was used to balance the pressure inside the equilibrator with the total gas tension. The equilibrator has an e-folding time of 7.36 ± 0.74 min for oxygen and oxygen isotopes, allowing changes on hourly time scales to be easily resolved. The equilibrator delivers ?equilibrated? air at a flow rate of 3 mL min?1 to an isotope ratio mass spectrometer. The high gas sampling flow rate would allow the equilibrator to be interfaced with many potential devices, but further development may be required for use at sea. This system was tested at the Scripps Institution of Oceanography pier, in La Jolla, California. A mathematical model validated with performance tests was used to assess the sensitivity of the equilibrated air composition to headspace pressure and makeup gas composition. Parameters in this model can be quantified to establish corrections under different operating conditions. For typical observed values, under the operating conditions presented here, the uncertainty in the measurement due to the equilibrator system is 2.2 per mil for δ(O2/N2), 1.5 per mil for δ(O2/Ar), 0.059 per mil for δ18O, and 0.0030 per mil for ?17O.
    • Download: (1.385Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      An Equilibrator System to Measure Dissolved Oxygen and Its Isotopes

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4228091
    Collections
    • Journal of Atmospheric and Oceanic Technology

    Show full item record

    contributor authorRafelski, Lauren Elmegreen
    contributor authorPaplawsky, Bill
    contributor authorKeeling, Ralph F.
    date accessioned2017-06-09T17:24:36Z
    date available2017-06-09T17:24:36Z
    date copyright2013/02/01
    date issued2012
    identifier issn0739-0572
    identifier otherams-84723.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4228091
    description abstractn equilibrator is presented that is designed to have a sufficient equilibration time even for insoluble gases, and to minimize artifacts associated with not equilibrating to the total gas tension. A gas tension device was used to balance the pressure inside the equilibrator with the total gas tension. The equilibrator has an e-folding time of 7.36 ± 0.74 min for oxygen and oxygen isotopes, allowing changes on hourly time scales to be easily resolved. The equilibrator delivers ?equilibrated? air at a flow rate of 3 mL min?1 to an isotope ratio mass spectrometer. The high gas sampling flow rate would allow the equilibrator to be interfaced with many potential devices, but further development may be required for use at sea. This system was tested at the Scripps Institution of Oceanography pier, in La Jolla, California. A mathematical model validated with performance tests was used to assess the sensitivity of the equilibrated air composition to headspace pressure and makeup gas composition. Parameters in this model can be quantified to establish corrections under different operating conditions. For typical observed values, under the operating conditions presented here, the uncertainty in the measurement due to the equilibrator system is 2.2 per mil for δ(O2/N2), 1.5 per mil for δ(O2/Ar), 0.059 per mil for δ18O, and 0.0030 per mil for ?17O.
    publisherAmerican Meteorological Society
    titleAn Equilibrator System to Measure Dissolved Oxygen and Its Isotopes
    typeJournal Paper
    journal volume30
    journal issue2
    journal titleJournal of Atmospheric and Oceanic Technology
    identifier doi10.1175/JTECH-D-12-00074.1
    journal fristpage361
    journal lastpage377
    treeJournal of Atmospheric and Oceanic Technology:;2012:;volume( 030 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian