YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • AMS
    • Journal of Atmospheric and Oceanic Technology
    • View Item
    •   YE&T Library
    • AMS
    • Journal of Atmospheric and Oceanic Technology
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Evaluation of a Triple-Axis Coherent Doppler Velocity Profiler for Measuring Near-Bed Flow: A Field Study

    Source: Journal of Atmospheric and Oceanic Technology:;2006:;volume( 023 ):;issue: 001::page 90
    Author:
    Betteridge, K. F. E.
    ,
    Bell, P. S.
    ,
    Thorne, P. D.
    ,
    Williams, J. J.
    DOI: 10.1175/JTECH1834.1
    Publisher: American Meteorological Society
    Abstract: Collocated detailed measurements of near-bed turbulent and intrawave flow are important for studying sediment transport processes and seabed evolution. Existing commercially available triple-axis profiling instruments do not provide collocated velocity measurements. To improve the capability to make such measurements a triple-axis coherent Doppler velocity profiler (CDVP) has been developed and tested in the marine environment. The instrument was designed to measure orthogonal velocity profiles within a narrow column of water at 16 Hz within 1 m of the bed with a vertical spatial resolution of 0.05 m. This paper describes the first deployment of the instrument, in a tidal inlet in Portugal during a multidisciplinary study, when CDVP flow velocity measurements were compared with data from other instrumentation. A pragmatic approach was adopted to assess the capability of the triple-axis CDVP, using both an evaluation of internal consistency and an assessment against two commercially available acoustic Doppler velocimeters (ADVs). Measurements of the mean and fluctuating velocity profiles were collected with the triple-axis CDVP, and these have been shown to be internally consistent and to be in good agreement with measurements obtained with the ADVs.
    • Download: (2.577Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Evaluation of a Triple-Axis Coherent Doppler Velocity Profiler for Measuring Near-Bed Flow: A Field Study

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4227530
    Collections
    • Journal of Atmospheric and Oceanic Technology

    Show full item record

    contributor authorBetteridge, K. F. E.
    contributor authorBell, P. S.
    contributor authorThorne, P. D.
    contributor authorWilliams, J. J.
    date accessioned2017-06-09T17:23:03Z
    date available2017-06-09T17:23:03Z
    date copyright2006/01/01
    date issued2006
    identifier issn0739-0572
    identifier otherams-84218.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4227530
    description abstractCollocated detailed measurements of near-bed turbulent and intrawave flow are important for studying sediment transport processes and seabed evolution. Existing commercially available triple-axis profiling instruments do not provide collocated velocity measurements. To improve the capability to make such measurements a triple-axis coherent Doppler velocity profiler (CDVP) has been developed and tested in the marine environment. The instrument was designed to measure orthogonal velocity profiles within a narrow column of water at 16 Hz within 1 m of the bed with a vertical spatial resolution of 0.05 m. This paper describes the first deployment of the instrument, in a tidal inlet in Portugal during a multidisciplinary study, when CDVP flow velocity measurements were compared with data from other instrumentation. A pragmatic approach was adopted to assess the capability of the triple-axis CDVP, using both an evaluation of internal consistency and an assessment against two commercially available acoustic Doppler velocimeters (ADVs). Measurements of the mean and fluctuating velocity profiles were collected with the triple-axis CDVP, and these have been shown to be internally consistent and to be in good agreement with measurements obtained with the ADVs.
    publisherAmerican Meteorological Society
    titleEvaluation of a Triple-Axis Coherent Doppler Velocity Profiler for Measuring Near-Bed Flow: A Field Study
    typeJournal Paper
    journal volume23
    journal issue1
    journal titleJournal of Atmospheric and Oceanic Technology
    identifier doi10.1175/JTECH1834.1
    journal fristpage90
    journal lastpage106
    treeJournal of Atmospheric and Oceanic Technology:;2006:;volume( 023 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian