YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • AMS
    • Journal of Atmospheric and Oceanic Technology
    • View Item
    •   YE&T Library
    • AMS
    • Journal of Atmospheric and Oceanic Technology
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Evaluation of the Dropsonde Humidity Sensor Using Data from DYCOMS-II and IHOP_2002

    Source: Journal of Atmospheric and Oceanic Technology:;2005:;volume( 022 ):;issue: 003::page 247
    Author:
    Wang, Junhong
    DOI: 10.1175/JTECH1698.1
    Publisher: American Meteorological Society
    Abstract: The dropsonde humidity data have not been fully utilized due to lack of knowledge on performance of the dropsonde humidity sensor. This study evaluates the performance of the dropsonde humidity sensor using data collected from two field experiments, the Dynamics and Chemistry of Marine Stratocumulus Phase II: Entrainment Studies (DYCOMS-II) and the International H2O Project (IHOP)_2002. During DYCOMS-II, 63 dropsondes were dropped above marine stratocumulus clouds. It provides a unique opportunity to evaluate the performance of the dropsonde humidity sensor within clouds. Relative humidity (RH) inside clouds did not reach 100% all the time, but the maximum RH reached 100% for 28% of soundings and was within the sensor accuracy range (94%?100%). This suggests that the dropsonde humidity sensor displays no systematic dry bias near saturation. The dropsonde humidity sensor experienced large time-lag errors when it descended from a dry environment above clouds into clouds. The mean estimated time constant of the sensor is 5 s at 15°C, which is much larger than 0.5 s at 20°C given by the manufacturer. The humidity sensor still reported near-saturation RH after it exited clouds because of water on the sensor. The approximately coincident dropsonde and aircraft temperature data during DYCOMS-II show that the dropsonde underestimates temperatures inside and below clouds by averages of 0.21° and 0.93°C, respectively. Seventy-one pairs of dropsonde and radiosonde soundings during IHOP_2002 were launched within a half hour and 50 km and sampled the same air mass based on the visual examination. The comparisons show that the dropsonde and radiosonde RH data agree with each other within ±2% RH, suggesting no systematic dry bias in dropsonde humidity data. However, dropsonde-measured temperature is consistently colder than that by radiosonde by ?0.4°C.
    • Download: (589.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Evaluation of the Dropsonde Humidity Sensor Using Data from DYCOMS-II and IHOP_2002

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4227379
    Collections
    • Journal of Atmospheric and Oceanic Technology

    Show full item record

    contributor authorWang, Junhong
    date accessioned2017-06-09T17:22:41Z
    date available2017-06-09T17:22:41Z
    date copyright2005/03/01
    date issued2005
    identifier issn0739-0572
    identifier otherams-84082.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4227379
    description abstractThe dropsonde humidity data have not been fully utilized due to lack of knowledge on performance of the dropsonde humidity sensor. This study evaluates the performance of the dropsonde humidity sensor using data collected from two field experiments, the Dynamics and Chemistry of Marine Stratocumulus Phase II: Entrainment Studies (DYCOMS-II) and the International H2O Project (IHOP)_2002. During DYCOMS-II, 63 dropsondes were dropped above marine stratocumulus clouds. It provides a unique opportunity to evaluate the performance of the dropsonde humidity sensor within clouds. Relative humidity (RH) inside clouds did not reach 100% all the time, but the maximum RH reached 100% for 28% of soundings and was within the sensor accuracy range (94%?100%). This suggests that the dropsonde humidity sensor displays no systematic dry bias near saturation. The dropsonde humidity sensor experienced large time-lag errors when it descended from a dry environment above clouds into clouds. The mean estimated time constant of the sensor is 5 s at 15°C, which is much larger than 0.5 s at 20°C given by the manufacturer. The humidity sensor still reported near-saturation RH after it exited clouds because of water on the sensor. The approximately coincident dropsonde and aircraft temperature data during DYCOMS-II show that the dropsonde underestimates temperatures inside and below clouds by averages of 0.21° and 0.93°C, respectively. Seventy-one pairs of dropsonde and radiosonde soundings during IHOP_2002 were launched within a half hour and 50 km and sampled the same air mass based on the visual examination. The comparisons show that the dropsonde and radiosonde RH data agree with each other within ±2% RH, suggesting no systematic dry bias in dropsonde humidity data. However, dropsonde-measured temperature is consistently colder than that by radiosonde by ?0.4°C.
    publisherAmerican Meteorological Society
    titleEvaluation of the Dropsonde Humidity Sensor Using Data from DYCOMS-II and IHOP_2002
    typeJournal Paper
    journal volume22
    journal issue3
    journal titleJournal of Atmospheric and Oceanic Technology
    identifier doi10.1175/JTECH1698.1
    journal fristpage247
    journal lastpage257
    treeJournal of Atmospheric and Oceanic Technology:;2005:;volume( 022 ):;issue: 003
    contenttypeFulltext