YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • AMS
    • Journal of the Atmospheric Sciences
    • View Item
    •   YE&T Library
    • AMS
    • Journal of the Atmospheric Sciences
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Impacts of Updraft Size and Dimensionality on the Perturbation Pressure and Vertical Velocity in Cumulus Convection. Part I: Simple, Generalized Analytic Solutions

    Source: Journal of the Atmospheric Sciences:;2015:;Volume( 073 ):;issue: 004::page 1441
    Author:
    Morrison, Hugh
    DOI: 10.1175/JAS-D-15-0040.1
    Publisher: American Meteorological Society
    Abstract: his study investigates relationships between vertical velocity, perturbation pressure, updraft size, and dimensionality for cumulus convection. Generalized theoretical expressions are derived from approximate analytic solutions of the governing momentum and mass continuity equations for both two-dimensional (2D) and axisymmetric quasi-three-dimensional (3D) steady-state updrafts. These expressions relate perturbation pressure and vertical velocity to updraft radius R, height H, and thermal buoyancy. They suggest that the vertical velocity at the level of neutral buoyancy is reduced from perturbation pressure effects by factors of and in 2D and 3D, respectively, where is a nondimensional length, with somewhat different scalings lower in the updraft (α is a parameter equal to the ratio of vertical velocity horizontally averaged across the updraft to that at the updraft center). They also indicate that updrafts are weaker in 2D than 3D, all else being equal, with a difference of up to a factor of 2 in vertical velocity for as a direct result of differences in mass continuity between 2D and axisymmetric 3D flow. Differences between these expressions and other analytic solutions, including those derived from single normal mode Fourier/Fourier?Bessel expansion of the buoyant perturbation pressure Poisson equation, are discussed. Part II of this study compares the theoretical expressions with numerical solutions of the buoyant perturbation pressure Poisson equation for a wide range of thermal buoyancy profiles representing shallow-to-deep moist convection and also with fully dynamical 2D and 3D updraft simulations.
    • Download: (1.586Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Impacts of Updraft Size and Dimensionality on the Perturbation Pressure and Vertical Velocity in Cumulus Convection. Part I: Simple, Generalized Analytic Solutions

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4219846
    Collections
    • Journal of the Atmospheric Sciences

    Show full item record

    contributor authorMorrison, Hugh
    date accessioned2017-06-09T16:58:31Z
    date available2017-06-09T16:58:31Z
    date copyright2016/04/01
    date issued2015
    identifier issn0022-4928
    identifier otherams-77302.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4219846
    description abstracthis study investigates relationships between vertical velocity, perturbation pressure, updraft size, and dimensionality for cumulus convection. Generalized theoretical expressions are derived from approximate analytic solutions of the governing momentum and mass continuity equations for both two-dimensional (2D) and axisymmetric quasi-three-dimensional (3D) steady-state updrafts. These expressions relate perturbation pressure and vertical velocity to updraft radius R, height H, and thermal buoyancy. They suggest that the vertical velocity at the level of neutral buoyancy is reduced from perturbation pressure effects by factors of and in 2D and 3D, respectively, where is a nondimensional length, with somewhat different scalings lower in the updraft (α is a parameter equal to the ratio of vertical velocity horizontally averaged across the updraft to that at the updraft center). They also indicate that updrafts are weaker in 2D than 3D, all else being equal, with a difference of up to a factor of 2 in vertical velocity for as a direct result of differences in mass continuity between 2D and axisymmetric 3D flow. Differences between these expressions and other analytic solutions, including those derived from single normal mode Fourier/Fourier?Bessel expansion of the buoyant perturbation pressure Poisson equation, are discussed. Part II of this study compares the theoretical expressions with numerical solutions of the buoyant perturbation pressure Poisson equation for a wide range of thermal buoyancy profiles representing shallow-to-deep moist convection and also with fully dynamical 2D and 3D updraft simulations.
    publisherAmerican Meteorological Society
    titleImpacts of Updraft Size and Dimensionality on the Perturbation Pressure and Vertical Velocity in Cumulus Convection. Part I: Simple, Generalized Analytic Solutions
    typeJournal Paper
    journal volume73
    journal issue4
    journal titleJournal of the Atmospheric Sciences
    identifier doi10.1175/JAS-D-15-0040.1
    journal fristpage1441
    journal lastpage1454
    treeJournal of the Atmospheric Sciences:;2015:;Volume( 073 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian