contributor author | Stull, Roland | |
date accessioned | 2017-06-09T16:48:38Z | |
date available | 2017-06-09T16:48:38Z | |
date copyright | 2011/11/01 | |
date issued | 2011 | |
identifier issn | 1558-8424 | |
identifier other | ams-74545.pdf | |
identifier uri | http://onlinelibrary.yabesh.ir/handle/yetl/4216782 | |
description abstract | n equation is presented for wet-bulb temperature as a function of air temperature and relative humidity at standard sea level pressure. It was found as an empirical fit using gene-expression programming. This equation is valid for relative humidities between 5% and 99% and for air temperatures between ?20° and 50°C, except for situations having both low humidity and cold temperature. Over the valid range, errors in wet-bulb temperature range from ?1° to +0.65°C, with mean absolute error of less than 0.3°C. | |
publisher | American Meteorological Society | |
title | Wet-Bulb Temperature from Relative Humidity and Air Temperature | |
type | Journal Paper | |
journal volume | 50 | |
journal issue | 11 | |
journal title | Journal of Applied Meteorology and Climatology | |
identifier doi | 10.1175/JAMC-D-11-0143.1 | |
journal fristpage | 2267 | |
journal lastpage | 2269 | |
tree | Journal of Applied Meteorology and Climatology:;2011:;volume( 050 ):;issue: 011 | |
contenttype | Fulltext | |