    Surface Analysis near and within the Tipton, Kansas, Tornado on 29 May 2008

    Source: Monthly Weather Review:;2010:;volume( 139 ):;issue: 002::page 370
    Author:
    Lee, Bruce D.
    ,
    Finley, Catherine A.
    ,
    Samaras, Timothy M.
    DOI: 10.1175/2010MWR3454.1
    Publisher: American Meteorological Society
    Abstract: Data collected by a mesonet within the near-tornado environment and in the Tipton tornado on 29 May 2008 provided a rare opportunity to analyze rear-flank downdraft (RFD) outflow properties closely bounding a tornado and to characterize parcel thermodynamics being ingested into a tornado from the rear-flank downdraft. Parcels moving into the tornado on its right flank had very small negative buoyancy and considerable potential buoyancy. Measurements within and very near the tornado showed similar buoyancy characteristics to the storm inflow. Analyzed surface divergence and videographic evidence indicated that the RFD outflow just to the right and wrapping in front of the tornado was supported by parcels moving out of a narrow downdraft bordering the right flank of the tornado. Surface flow field analysis showed that parcels moved out of the downdraft-associated divergence region and into the right side of, as well as in front of, the tornado. An internal RFD surge boundary was positioned roughly 0.5 km in front of the eastern edge of the analyzed divergence region and implied downdraft. The broader RFD outflow thermodynamic characteristics were consistent with recent research with only small negative buoyancy and substantial potential buoyancy; however, convective inhibition was considerably higher than typically found in other tornadic cases. This latter characteristic was emblematic of the broader storm environment on this day. Parcels making up the RFD outflow originated from low-levels, consistent with recent findings for tornadic rear-flank downdrafts and in contrast to past historical indications for the rear-flank downdraft source region.
    • Download: (3.257Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Surface Analysis near and within the Tipton, Kansas, Tornado on 29 May 2008

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4213265
    Collections
    • Monthly Weather Review

    Show full item record

    contributor authorLee, Bruce D.
    contributor authorFinley, Catherine A.
    contributor authorSamaras, Timothy M.
    date accessioned2017-06-09T16:38:18Z
    date available2017-06-09T16:38:18Z
    date copyright2011/02/01
    date issued2010
    identifier issn0027-0644
    identifier otherams-71380.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4213265
    description abstractData collected by a mesonet within the near-tornado environment and in the Tipton tornado on 29 May 2008 provided a rare opportunity to analyze rear-flank downdraft (RFD) outflow properties closely bounding a tornado and to characterize parcel thermodynamics being ingested into a tornado from the rear-flank downdraft. Parcels moving into the tornado on its right flank had very small negative buoyancy and considerable potential buoyancy. Measurements within and very near the tornado showed similar buoyancy characteristics to the storm inflow. Analyzed surface divergence and videographic evidence indicated that the RFD outflow just to the right and wrapping in front of the tornado was supported by parcels moving out of a narrow downdraft bordering the right flank of the tornado. Surface flow field analysis showed that parcels moved out of the downdraft-associated divergence region and into the right side of, as well as in front of, the tornado. An internal RFD surge boundary was positioned roughly 0.5 km in front of the eastern edge of the analyzed divergence region and implied downdraft. The broader RFD outflow thermodynamic characteristics were consistent with recent research with only small negative buoyancy and substantial potential buoyancy; however, convective inhibition was considerably higher than typically found in other tornadic cases. This latter characteristic was emblematic of the broader storm environment on this day. Parcels making up the RFD outflow originated from low-levels, consistent with recent findings for tornadic rear-flank downdrafts and in contrast to past historical indications for the rear-flank downdraft source region.
    publisherAmerican Meteorological Society
    titleSurface Analysis near and within the Tipton, Kansas, Tornado on 29 May 2008
    typeJournal Paper
    journal volume139
    journal issue2
    journal titleMonthly Weather Review
    identifier doi10.1175/2010MWR3454.1
    journal fristpage370
    journal lastpage386
    treeMonthly Weather Review:;2010:;volume( 139 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian