    A New Compact Cryogenic Air Sampler and Its Application in Stratospheric Greenhouse Gas Observation at Syowa Station, Antarctica

    Source: Journal of Atmospheric and Oceanic Technology:;2009:;volume( 026 ):;issue: 010::page 2182
    Author:
    Morimoto, Shinji
    ,
    Yamanouchi, Takashi
    ,
    Honda, Hideyuki
    ,
    Iijima, Issei
    ,
    Yoshida, Tetsuya
    ,
    Aoki, Shuji
    ,
    Nakazawa, Takakiyo
    ,
    Ishidoya, Shigeyuki
    ,
    Sugawara, Satoshi
    DOI: 10.1175/2009JTECHA1283.1
    Publisher: American Meteorological Society
    Abstract: To collect stratospheric air samples for greenhouse gas measurements, a compact cryogenic air sampler has been developed using a cooling device called the Joule?Thomson (J?T) minicooler. The J?T minicooler can produce liquefied neon within 5 s from high pressure neon gas precooled by liquid nitrogen. The sampler employs liquid neon as a refrigerant to solidify or liquefy sampled atmospheric constituents. Laboratory experiments showed that the sampler is capable of collecting about 3 and more than 7 L STP of air at 25 and 120 hPa, respectively, which corresponds to about 25 and 15 km above ground within 240 s, respectively. The new balloon-borne sampling system, which was set up for Antarctic experiments, consists of the compact sampler, a 2-L high pressure neon gas cylinder, pneumatic and solenoid valves, a controller with a GPS receiver, a telemetry transmitter, and batteries. The size of the sampling system is 300 mm width ? 300 mm depth ? 950 mm height and it weighs about 22 kg (including liquid nitrogen). Two of these compact sampling systems (configured for sampling at altitudes 18 and 25 km) were launched from Syowa Station (69.0°S, 39.5°E), Antarctica, in January 2008 using 1000 or 2000 m3 plastic balloons. They were launched successfully and recovered without any problem on sea ice on the same day as their launch. The collected stratospheric air samples showed reasonable concentrations of the stratospheric greenhouse gases over the Antarctic region.
    • Download: (1.027Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A New Compact Cryogenic Air Sampler and Its Application in Stratospheric Greenhouse Gas Observation at Syowa Station, Antarctica

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4210997
    Collections
    • Journal of Atmospheric and Oceanic Technology

    Show full item record

    contributor authorMorimoto, Shinji
    contributor authorYamanouchi, Takashi
    contributor authorHonda, Hideyuki
    contributor authorIijima, Issei
    contributor authorYoshida, Tetsuya
    contributor authorAoki, Shuji
    contributor authorNakazawa, Takakiyo
    contributor authorIshidoya, Shigeyuki
    contributor authorSugawara, Satoshi
    date accessioned2017-06-09T16:31:19Z
    date available2017-06-09T16:31:19Z
    date copyright2009/10/01
    date issued2009
    identifier issn0739-0572
    identifier otherams-69339.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4210997
    description abstractTo collect stratospheric air samples for greenhouse gas measurements, a compact cryogenic air sampler has been developed using a cooling device called the Joule?Thomson (J?T) minicooler. The J?T minicooler can produce liquefied neon within 5 s from high pressure neon gas precooled by liquid nitrogen. The sampler employs liquid neon as a refrigerant to solidify or liquefy sampled atmospheric constituents. Laboratory experiments showed that the sampler is capable of collecting about 3 and more than 7 L STP of air at 25 and 120 hPa, respectively, which corresponds to about 25 and 15 km above ground within 240 s, respectively. The new balloon-borne sampling system, which was set up for Antarctic experiments, consists of the compact sampler, a 2-L high pressure neon gas cylinder, pneumatic and solenoid valves, a controller with a GPS receiver, a telemetry transmitter, and batteries. The size of the sampling system is 300 mm width ? 300 mm depth ? 950 mm height and it weighs about 22 kg (including liquid nitrogen). Two of these compact sampling systems (configured for sampling at altitudes 18 and 25 km) were launched from Syowa Station (69.0°S, 39.5°E), Antarctica, in January 2008 using 1000 or 2000 m3 plastic balloons. They were launched successfully and recovered without any problem on sea ice on the same day as their launch. The collected stratospheric air samples showed reasonable concentrations of the stratospheric greenhouse gases over the Antarctic region.
    publisherAmerican Meteorological Society
    titleA New Compact Cryogenic Air Sampler and Its Application in Stratospheric Greenhouse Gas Observation at Syowa Station, Antarctica
    typeJournal Paper
    journal volume26
    journal issue10
    journal titleJournal of Atmospheric and Oceanic Technology
    identifier doi10.1175/2009JTECHA1283.1
    journal fristpage2182
    journal lastpage2191
    treeJournal of Atmospheric and Oceanic Technology:;2009:;volume( 026 ):;issue: 010
    contenttypeFulltext