    Ten Years of TRMM/VIRS On-Orbit Calibrations and Multiyear Comparisons of VIRS and MODIS

    Source: Journal of Atmospheric and Oceanic Technology:;2008:;volume( 025 ):;issue: 012::page 2259
    Author:
    Lyu, Cheng-Hsuan
    ,
    Barnes, William L.
    DOI: 10.1175/2008JTECHA1110.1
    Publisher: American Meteorological Society
    Abstract: After 10 years of successful operation of the Tropical Rainfall Measuring Mission (TRMM)/Visible Infrared Scanner (VIRS), based on sensor performance, the authors have reexamined the calibration algorithms and identified several ways to improve the current VIRS level-1B radiometric calibration software. This study examines the trends in VIRS on-orbit calibration results by using lunar measurements to enable separation of the solar diffuser degradation from that of the VIRS Earth-viewing sensor and by comparing the radiometric data with two nearly identical Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on board the NASA Earth Observing System (EOS) Terra and Aqua satellites. For the VIRS, with spectral bands quite similar to several of the MODIS bands, the integrated lunar reflectance data were measured, from January 1998 to March 2007, at phase angles ranging from 0.94° to 121.8°. The authors present trending of the lunar data over periods of 4 yr (Aqua/MODIS), 6 yr (Terra/MODIS), and 10 yr (TRMM/VIRS) and use these observations to examine instrument radiometric stability. The VIRS-measured lunar irradiances are compared with the MODIS-measured lunar irradiances at phase angles around 54°?56°. With the upcoming modified VIRS level-1B version 7 calibration algorithm, the VIRS, along with MODIS, should provide better references for intercalibrating multiple Earth-observing sensors.
    • Download: (1.638Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Ten Years of TRMM/VIRS On-Orbit Calibrations and Multiyear Comparisons of VIRS and MODIS

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4209132
    Collections
    • Journal of Atmospheric and Oceanic Technology

    Show full item record

    contributor authorLyu, Cheng-Hsuan
    contributor authorBarnes, William L.
    date accessioned2017-06-09T16:25:36Z
    date available2017-06-09T16:25:36Z
    date copyright2008/12/01
    date issued2008
    identifier issn0739-0572
    identifier otherams-67661.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4209132
    description abstractAfter 10 years of successful operation of the Tropical Rainfall Measuring Mission (TRMM)/Visible Infrared Scanner (VIRS), based on sensor performance, the authors have reexamined the calibration algorithms and identified several ways to improve the current VIRS level-1B radiometric calibration software. This study examines the trends in VIRS on-orbit calibration results by using lunar measurements to enable separation of the solar diffuser degradation from that of the VIRS Earth-viewing sensor and by comparing the radiometric data with two nearly identical Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on board the NASA Earth Observing System (EOS) Terra and Aqua satellites. For the VIRS, with spectral bands quite similar to several of the MODIS bands, the integrated lunar reflectance data were measured, from January 1998 to March 2007, at phase angles ranging from 0.94° to 121.8°. The authors present trending of the lunar data over periods of 4 yr (Aqua/MODIS), 6 yr (Terra/MODIS), and 10 yr (TRMM/VIRS) and use these observations to examine instrument radiometric stability. The VIRS-measured lunar irradiances are compared with the MODIS-measured lunar irradiances at phase angles around 54°?56°. With the upcoming modified VIRS level-1B version 7 calibration algorithm, the VIRS, along with MODIS, should provide better references for intercalibrating multiple Earth-observing sensors.
    publisherAmerican Meteorological Society
    titleTen Years of TRMM/VIRS On-Orbit Calibrations and Multiyear Comparisons of VIRS and MODIS
    typeJournal Paper
    journal volume25
    journal issue12
    journal titleJournal of Atmospheric and Oceanic Technology
    identifier doi10.1175/2008JTECHA1110.1
    journal fristpage2259
    journal lastpage2270
    treeJournal of Atmospheric and Oceanic Technology:;2008:;volume( 025 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian