YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • AMS
    • Journal of Climate
    • View Item
    •   YE&T Library
    • AMS
    • Journal of Climate
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    A Method to Adjust Long-Term Temperature Extreme Series for Nonclimatic Inhomogeneities

    Source: Journal of Climate:;2000:;volume( 013 ):;issue: 020::page 3680
    Author:
    Allen, Robert J.
    ,
    DeGaetano, Arthur T.
    DOI: 10.1175/1520-0442(2000)013<3680:AMTALT>2.0.CO;2
    Publisher: American Meteorological Society
    Abstract: A method to homogenize nonclimatic discontinuities in temperature extreme exceedence series is developed and evaluated. The method is based on a set of complementary tests with the application of an individual test depending on the availability of an adequate network of nearby homogeneous reference stations and the presence of significant trends in the resulting difference or original exceedence series. Given a suitable set of neighboring reference stations, a comparison of the differences in exceedences between the inhomogeneous station and neighboring sites is made for the periods before and after the documented discontinuity. In the absence of one or more reference stations, the exceedences at the inhomogeneous station are compared before and after the nonclimatic change. A method by which nonstationary series are detrended and subsequently evaluated is also presented. When tested using homogenized data series into which an artificial discontinuity of known magnitude was introduced, as many as 80% of the ±1°F discontinuities were detected by the difference series approach. The performance of the single-station exceedence series test was less accurate. Although in a few cases, less than 40% of the ±1°F discontinuities were detected, between 60% and 76% of the ±2°F discontinuities were identified. Using both tests, the probability of falsely detecting a discontinuity (i.e., identifying an inhomogeneity when none existed) was 5%. Provided both methods deemed a documented inhomogeneity significant, the magnitude of the adjustments imposed by both methods was similar.
    • Download: (387.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Method to Adjust Long-Term Temperature Extreme Series for Nonclimatic Inhomogeneities

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4196067
    Collections
    • Journal of Climate

    Show full item record

    contributor authorAllen, Robert J.
    contributor authorDeGaetano, Arthur T.
    date accessioned2017-06-09T15:53:03Z
    date available2017-06-09T15:53:03Z
    date copyright2000/10/01
    date issued2000
    identifier issn0894-8755
    identifier otherams-5590.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4196067
    description abstractA method to homogenize nonclimatic discontinuities in temperature extreme exceedence series is developed and evaluated. The method is based on a set of complementary tests with the application of an individual test depending on the availability of an adequate network of nearby homogeneous reference stations and the presence of significant trends in the resulting difference or original exceedence series. Given a suitable set of neighboring reference stations, a comparison of the differences in exceedences between the inhomogeneous station and neighboring sites is made for the periods before and after the documented discontinuity. In the absence of one or more reference stations, the exceedences at the inhomogeneous station are compared before and after the nonclimatic change. A method by which nonstationary series are detrended and subsequently evaluated is also presented. When tested using homogenized data series into which an artificial discontinuity of known magnitude was introduced, as many as 80% of the ±1°F discontinuities were detected by the difference series approach. The performance of the single-station exceedence series test was less accurate. Although in a few cases, less than 40% of the ±1°F discontinuities were detected, between 60% and 76% of the ±2°F discontinuities were identified. Using both tests, the probability of falsely detecting a discontinuity (i.e., identifying an inhomogeneity when none existed) was 5%. Provided both methods deemed a documented inhomogeneity significant, the magnitude of the adjustments imposed by both methods was similar.
    publisherAmerican Meteorological Society
    titleA Method to Adjust Long-Term Temperature Extreme Series for Nonclimatic Inhomogeneities
    typeJournal Paper
    journal volume13
    journal issue20
    journal titleJournal of Climate
    identifier doi10.1175/1520-0442(2000)013<3680:AMTALT>2.0.CO;2
    journal fristpage3680
    journal lastpage3695
    treeJournal of Climate:;2000:;volume( 013 ):;issue: 020
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian