YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • AMS
    • Journal of Atmospheric and Oceanic Technology
    • View Item
    •   YE&T Library
    • AMS
    • Journal of Atmospheric and Oceanic Technology
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    An Open Path, Fast Response IR Spectrometer for Simultaneous Detection of C02 and Water Vapor Fluctuations

    Source: Journal of Atmospheric and Oceanic Technology:;1989:;volume( 006 ):;issue: 004::page 624
    Author:
    Heikinheimo, M. J.
    ,
    Thurtell, G. W.
    ,
    Kidd, G. E.
    DOI: 10.1175/1520-0426(1989)006<0624:AOPFRI>2.0.CO;2
    Publisher: American Meteorological Society
    Abstract: A fast response C02 and water vapor (H2O) analyzer was developed in this study for the measurement of atmospheric turbulence fluctuations and, in conjunction with a fast response anemometer, transport of these entities. High speed and high resolution detection of C02 and H2O was accomplished simultaneously for the same air sample with open path IR absorption techniques. The miniature size sensor features a once folded 12.5 cm pathlength. The sensor structure and sampling technique provided direct compensation for undesirable factors (e.g., dust) affecting transmission of IR-radiation in the optical path and for the changes in source intensity and detector response due to sensor temperature fluctuations. The rms-noise level of the C02 and H2O outputs corresponded to 0.3 ppm and 0.02 g m?2 fluctuations respectively, when absorbing gases were removed from the path. Spectral analysis showed that the noise was well below the signal level for both gases within the frequency range from 0.002 to 5 Hz. In comparison with the commercially available Lyman-α hygrometer the H2O output noise level of the IR-sensor was a factor of two larger, but the simultaneously measured signal spectra and also the latent heat flux values obtained with the two sensors in the field were practically identical. The IR-sensor produced C02 flux values that were comparable to those reported in the literature.
    • Download: (1.024Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      An Open Path, Fast Response IR Spectrometer for Simultaneous Detection of C02 and Water Vapor Fluctuations

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4189177
    Collections
    • Journal of Atmospheric and Oceanic Technology

    Show full item record

    contributor authorHeikinheimo, M. J.
    contributor authorThurtell, G. W.
    contributor authorKidd, G. E.
    date accessioned2017-06-09T15:39:02Z
    date available2017-06-09T15:39:02Z
    date copyright1989/08/01
    date issued1989
    identifier issn0739-0572
    identifier otherams-497.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4189177
    description abstractA fast response C02 and water vapor (H2O) analyzer was developed in this study for the measurement of atmospheric turbulence fluctuations and, in conjunction with a fast response anemometer, transport of these entities. High speed and high resolution detection of C02 and H2O was accomplished simultaneously for the same air sample with open path IR absorption techniques. The miniature size sensor features a once folded 12.5 cm pathlength. The sensor structure and sampling technique provided direct compensation for undesirable factors (e.g., dust) affecting transmission of IR-radiation in the optical path and for the changes in source intensity and detector response due to sensor temperature fluctuations. The rms-noise level of the C02 and H2O outputs corresponded to 0.3 ppm and 0.02 g m?2 fluctuations respectively, when absorbing gases were removed from the path. Spectral analysis showed that the noise was well below the signal level for both gases within the frequency range from 0.002 to 5 Hz. In comparison with the commercially available Lyman-α hygrometer the H2O output noise level of the IR-sensor was a factor of two larger, but the simultaneously measured signal spectra and also the latent heat flux values obtained with the two sensors in the field were practically identical. The IR-sensor produced C02 flux values that were comparable to those reported in the literature.
    publisherAmerican Meteorological Society
    titleAn Open Path, Fast Response IR Spectrometer for Simultaneous Detection of C02 and Water Vapor Fluctuations
    typeJournal Paper
    journal volume6
    journal issue4
    journal titleJournal of Atmospheric and Oceanic Technology
    identifier doi10.1175/1520-0426(1989)006<0624:AOPFRI>2.0.CO;2
    journal fristpage624
    journal lastpage636
    treeJournal of Atmospheric and Oceanic Technology:;1989:;volume( 006 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian