Coincidence and Dead-Time Corrections for Particles Counters. Part II: High Concentration Measurements with an FSSPSource: Journal of Atmospheric and Oceanic Technology:;1989:;volume( 006 ):;issue: 004::page 585Author:Brenguier, J. L.
DOI: 10.1175/1520-0426(1989)006<0585:CADTCF>2.0.CO;2Publisher: American Meteorological Society
Abstract: Meat of the procedures proposed in the past to correct the coincidence and dead time losses in droplet counters FSSP* or ASSP** are based on empirical formulae. A more rigorous analysis of the statistical behavior of these counters yields a better estimate of the high droplet concentration measurements and moreover, it becomes possible to explain the fluctuations of the operating characteristics of the probes (rejection criteria). A new method is then proposed to detect heterogeneities at scales smaller than the sampling scale and to estimate the concentration peak values in the sample, with the current parameters measured by the FSSP.
|
Collections
Show full item record
contributor author | Brenguier, J. L. | |
date accessioned | 2017-06-09T15:38:23Z | |
date available | 2017-06-09T15:38:23Z | |
date copyright | 1989/08/01 | |
date issued | 1989 | |
identifier issn | 0739-0572 | |
identifier other | ams-494.pdf | |
identifier uri | http://onlinelibrary.yabesh.ir/handle/yetl/4188844 | |
description abstract | Meat of the procedures proposed in the past to correct the coincidence and dead time losses in droplet counters FSSP* or ASSP** are based on empirical formulae. A more rigorous analysis of the statistical behavior of these counters yields a better estimate of the high droplet concentration measurements and moreover, it becomes possible to explain the fluctuations of the operating characteristics of the probes (rejection criteria). A new method is then proposed to detect heterogeneities at scales smaller than the sampling scale and to estimate the concentration peak values in the sample, with the current parameters measured by the FSSP. | |
publisher | American Meteorological Society | |
title | Coincidence and Dead-Time Corrections for Particles Counters. Part II: High Concentration Measurements with an FSSP | |
type | Journal Paper | |
journal volume | 6 | |
journal issue | 4 | |
journal title | Journal of Atmospheric and Oceanic Technology | |
identifier doi | 10.1175/1520-0426(1989)006<0585:CADTCF>2.0.CO;2 | |
journal fristpage | 585 | |
journal lastpage | 598 | |
tree | Journal of Atmospheric and Oceanic Technology:;1989:;volume( 006 ):;issue: 004 | |
contenttype | Fulltext |