    Coincidence and Dead-Time Corrections for Particles Counters. Part II: High Concentration Measurements with an FSSP

    Source: Journal of Atmospheric and Oceanic Technology:;1989:;volume( 006 ):;issue: 004::page 585
    Author:
    Brenguier, J. L.
    DOI: 10.1175/1520-0426(1989)006<0585:CADTCF>2.0.CO;2
    Publisher: American Meteorological Society
    Abstract: Meat of the procedures proposed in the past to correct the coincidence and dead time losses in droplet counters FSSP* or ASSP** are based on empirical formulae. A more rigorous analysis of the statistical behavior of these counters yields a better estimate of the high droplet concentration measurements and moreover, it becomes possible to explain the fluctuations of the operating characteristics of the probes (rejection criteria). A new method is then proposed to detect heterogeneities at scales smaller than the sampling scale and to estimate the concentration peak values in the sample, with the current parameters measured by the FSSP.
    • Download: (1.108Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Coincidence and Dead-Time Corrections for Particles Counters. Part II: High Concentration Measurements with an FSSP

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4188844
    Collections
    • Journal of Atmospheric and Oceanic Technology

    Show full item record

    contributor authorBrenguier, J. L.
    date accessioned2017-06-09T15:38:23Z
    date available2017-06-09T15:38:23Z
    date copyright1989/08/01
    date issued1989
    identifier issn0739-0572
    identifier otherams-494.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4188844
    description abstractMeat of the procedures proposed in the past to correct the coincidence and dead time losses in droplet counters FSSP* or ASSP** are based on empirical formulae. A more rigorous analysis of the statistical behavior of these counters yields a better estimate of the high droplet concentration measurements and moreover, it becomes possible to explain the fluctuations of the operating characteristics of the probes (rejection criteria). A new method is then proposed to detect heterogeneities at scales smaller than the sampling scale and to estimate the concentration peak values in the sample, with the current parameters measured by the FSSP.
    publisherAmerican Meteorological Society
    titleCoincidence and Dead-Time Corrections for Particles Counters. Part II: High Concentration Measurements with an FSSP
    typeJournal Paper
    journal volume6
    journal issue4
    journal titleJournal of Atmospheric and Oceanic Technology
    identifier doi10.1175/1520-0426(1989)006<0585:CADTCF>2.0.CO;2
    journal fristpage585
    journal lastpage598
    treeJournal of Atmospheric and Oceanic Technology:;1989:;volume( 006 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian