YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • AMS
    • Journal of the Atmospheric Sciences
    • View Item
    •   YE&T Library
    • AMS
    • Journal of the Atmospheric Sciences
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Electrification of the Hurricane

    Source: Journal of the Atmospheric Sciences:;1999:;Volume( 056 ):;issue: 012::page 2004
    Author:
    Black, Robert A.
    ,
    Hallett, John
    DOI: 10.1175/1520-0469(1999)056<2004:EOTH>2.0.CO;2
    Publisher: American Meteorological Society
    Abstract: A survey of reports of electrical activity in hurricanes and typhoons from flight notes and personal experience (18 years, >230 eyewall penetrations for R. A. Black; ?20 years for J. Hallett, plus that of others at the Hurricane Research Division), and perusal of flight notes dating from 1980, show that lightning in and within 100 km or so of the eyewall is usually sparse. However, occasionally, significant electrical activity (>one flash per minute) occurs in or near the eyewall. National Oceanic and Atmospheric Administration WP-3D aircraft penetrations through a number of storms relate the lightning occurrence to strong vertical velocity (>10 m s?1) and the presence of supercooled liquid cloud droplets extending to temperatures below ?20°C. Specific measurements of cloud properties during eyewall penetrations show that the supercooled cloud water content increases with upward velocities >?5.0 m s?1, as does the presence of large (>2 mm) supercooled drops. Measurements at temperatures >?13°C show that the transition of supercooled cloud water to ice along an outward radial in all systems is associated with local electric fields (occasionally >20 kV m?1) and negative charge above positive charge. In systems with stronger vertical velocity there is a larger region of supercooled cloud extending to lower temperatures where charge separation may occur, as judged by the presence of regions containing graupel, small ice, and cloud droplets. The ratio of ice to supercooled water increases radially outward from the eyewall and depends upon altitude (temperature). The spatial distribution of charge is further influenced by the relation of vertical velocity to the radial flow, with the upper charge regions tending to be advected outward. In symmetrical, mature hurricanes, supercooled water usually occurs only in regions at temperatures above about ?5°C. The upward transport of supercooled cloud water is limited by a balance between water condensed in the eyewall updraft and its erosion by ice in downdrafts descending in the outward regions of the eyewall. This ice originates from both primary and secondary ice nucleation in the updraft. This is consistent with an exponential increase in ice concentration, as the rate at which the ice particle concentrations increase depends on the production of secondary particles by preexisting graupel, some of which ultimately grow into new graupel, and its outward transport in the anvil flow aloft. Penetrations at temperatures as low as ?15°C show the presence of electric fields consistent with specific laboratory-derived criteria for charge separated during ice?graupel collisions, given that a liquid water?dependent sign reversal temperature may occur. Such a reversal may result from either a changing temperature in the vertical, a changing cloud liquid water content in the horizontal, or a combination of the two. Since cloud-to-ground (CG) lightning can be observed with remote detection networks that provide the polarity and frequency of CG lightning, there is potential that hurricane evolution may be detected remotely and that lightning may be usable as an indicator of a change in the storm intensity and/or track.
    • Download: (647.9Kb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Electrification of the Hurricane

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4158810
    Collections
    • Journal of the Atmospheric Sciences

    Show full item record

    contributor authorBlack, Robert A.
    contributor authorHallett, John
    date accessioned2017-06-09T14:35:31Z
    date available2017-06-09T14:35:31Z
    date copyright1999/06/01
    date issued1999
    identifier issn0022-4928
    identifier otherams-22368.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4158810
    description abstractA survey of reports of electrical activity in hurricanes and typhoons from flight notes and personal experience (18 years, >230 eyewall penetrations for R. A. Black; ?20 years for J. Hallett, plus that of others at the Hurricane Research Division), and perusal of flight notes dating from 1980, show that lightning in and within 100 km or so of the eyewall is usually sparse. However, occasionally, significant electrical activity (>one flash per minute) occurs in or near the eyewall. National Oceanic and Atmospheric Administration WP-3D aircraft penetrations through a number of storms relate the lightning occurrence to strong vertical velocity (>10 m s?1) and the presence of supercooled liquid cloud droplets extending to temperatures below ?20°C. Specific measurements of cloud properties during eyewall penetrations show that the supercooled cloud water content increases with upward velocities >?5.0 m s?1, as does the presence of large (>2 mm) supercooled drops. Measurements at temperatures >?13°C show that the transition of supercooled cloud water to ice along an outward radial in all systems is associated with local electric fields (occasionally >20 kV m?1) and negative charge above positive charge. In systems with stronger vertical velocity there is a larger region of supercooled cloud extending to lower temperatures where charge separation may occur, as judged by the presence of regions containing graupel, small ice, and cloud droplets. The ratio of ice to supercooled water increases radially outward from the eyewall and depends upon altitude (temperature). The spatial distribution of charge is further influenced by the relation of vertical velocity to the radial flow, with the upper charge regions tending to be advected outward. In symmetrical, mature hurricanes, supercooled water usually occurs only in regions at temperatures above about ?5°C. The upward transport of supercooled cloud water is limited by a balance between water condensed in the eyewall updraft and its erosion by ice in downdrafts descending in the outward regions of the eyewall. This ice originates from both primary and secondary ice nucleation in the updraft. This is consistent with an exponential increase in ice concentration, as the rate at which the ice particle concentrations increase depends on the production of secondary particles by preexisting graupel, some of which ultimately grow into new graupel, and its outward transport in the anvil flow aloft. Penetrations at temperatures as low as ?15°C show the presence of electric fields consistent with specific laboratory-derived criteria for charge separated during ice?graupel collisions, given that a liquid water?dependent sign reversal temperature may occur. Such a reversal may result from either a changing temperature in the vertical, a changing cloud liquid water content in the horizontal, or a combination of the two. Since cloud-to-ground (CG) lightning can be observed with remote detection networks that provide the polarity and frequency of CG lightning, there is potential that hurricane evolution may be detected remotely and that lightning may be usable as an indicator of a change in the storm intensity and/or track.
    publisherAmerican Meteorological Society
    titleElectrification of the Hurricane
    typeJournal Paper
    journal volume56
    journal issue12
    journal titleJournal of the Atmospheric Sciences
    identifier doi10.1175/1520-0469(1999)056<2004:EOTH>2.0.CO;2
    journal fristpage2004
    journal lastpage2028
    treeJournal of the Atmospheric Sciences:;1999:;Volume( 056 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian