    The Effect of Instrument Polarization Sensitivity on Sea Surface Remote Sensing with Infrared Spectroradiometers

    Source: Journal of Atmospheric and Oceanic Technology:;2002:;volume( 019 ):;issue: 005::page 820
    Author:
    Shaw, Joseph A.
    DOI: 10.1175/1520-0426(2002)019<0820:TEOIPS>2.0.CO;2
    Publisher: American Meteorological Society
    Abstract: The sensitivity of Fourier transform infrared spectroradiometers to the polarization state of incident radiance can become significant in radiometric measurements of a partially polarized source such as the sea surface. At off-nadir incidence angles and wavenumbers below about 2750 cm?1 (wavelengths longer than 3.6 ?m), radiance from the sea surface is partially vertically polarized, because the vertically polarized sea surface emission exceeds the horizontally polarized background reflection. At larger wavenumbers (wavelengths shorter than 3.6 ?m), reflected skylight becomes more significant, and the total radiance at off-nadir angles can become horizontally polarized. This paper shows how the inherent polarization sensitivity (?5%) of a typical Fourier transform infrared instrument leads to radiometric errors that are small (?0.1 K) but significant for radiometrically demanding sea surface remote sensing applications at large incidence angles. For incidence angles below approximately 45°, the polarization-induced error for longwave infrared measurements typically is less than approximately 0.05 K and therefore often can be neglected in sea surface radiometry. However, in polarimetric measurements used, for example, to increase contrast between man-made objects and the background, the instrument polarization sensitivity must be considered always.
    • Download: (184.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      The Effect of Instrument Polarization Sensitivity on Sea Surface Remote Sensing with Infrared Spectroradiometers

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4156144
    Collections
    • Journal of Atmospheric and Oceanic Technology

    Show full item record

    contributor authorShaw, Joseph A.
    date accessioned2017-06-09T14:28:40Z
    date available2017-06-09T14:28:40Z
    date copyright2002/05/01
    date issued2002
    identifier issn0739-0572
    identifier otherams-1997.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4156144
    description abstractThe sensitivity of Fourier transform infrared spectroradiometers to the polarization state of incident radiance can become significant in radiometric measurements of a partially polarized source such as the sea surface. At off-nadir incidence angles and wavenumbers below about 2750 cm?1 (wavelengths longer than 3.6 ?m), radiance from the sea surface is partially vertically polarized, because the vertically polarized sea surface emission exceeds the horizontally polarized background reflection. At larger wavenumbers (wavelengths shorter than 3.6 ?m), reflected skylight becomes more significant, and the total radiance at off-nadir angles can become horizontally polarized. This paper shows how the inherent polarization sensitivity (?5%) of a typical Fourier transform infrared instrument leads to radiometric errors that are small (?0.1 K) but significant for radiometrically demanding sea surface remote sensing applications at large incidence angles. For incidence angles below approximately 45°, the polarization-induced error for longwave infrared measurements typically is less than approximately 0.05 K and therefore often can be neglected in sea surface radiometry. However, in polarimetric measurements used, for example, to increase contrast between man-made objects and the background, the instrument polarization sensitivity must be considered always.
    publisherAmerican Meteorological Society
    titleThe Effect of Instrument Polarization Sensitivity on Sea Surface Remote Sensing with Infrared Spectroradiometers
    typeJournal Paper
    journal volume19
    journal issue5
    journal titleJournal of Atmospheric and Oceanic Technology
    identifier doi10.1175/1520-0426(2002)019<0820:TEOIPS>2.0.CO;2
    journal fristpage820
    journal lastpage827
    treeJournal of Atmospheric and Oceanic Technology:;2002:;volume( 019 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian