Comparison of Measurements of Atmospheric Wet Delay by Radiosonde, Water Vapor Radiometer, GPS, and VLBISource: Journal of Atmospheric and Oceanic Technology:;2001:;volume( 018 ):;issue: 006::page 830Author:Niell, A. E.
,
Coster, A. J.
,
Solheim, F. S.
,
Mendes, V. B.
,
Toor, P. C.
,
Langley, R. B.
,
Upham, C. A.
DOI: 10.1175/1520-0426(2001)018<0830:COMOAW>2.0.CO;2Publisher: American Meteorological Society
Abstract: The accuracy of the Global Positioning System (GPS) as an instrument for measuring the integrated water vapor content of the atmosphere has been evaluated by comparison with concurrent observations made over a 14-day period by radiosonde, microwave water vapor radiometer (WVR), and Very Long Baseline Interferometry (VLBI). The Vaisala RS-80 A-HUMICAP radiosondes required a correction to the relative humidity readings (provided by Vaisala) to account for packaging contamination; the WVR data required a correction in order to be consistent with the wet refractivity formulation of the VLBI, GPS, and radiosondes. The best agreement of zenith wet delay (ZWD) among the collocated WVR, radiosondes, VLBI, and GPS was for minimum elevations of the GPS measurements below 10°. After corrections were applied to the WVR and radiosonde measurements, WVR, GPS, and VLBI (with 5° minimum elevation angle cutoff) agreed within ?6 mm of ZWD [1 mm of precipitable water vapor (PWV)] when the differences were averaged, while the radiosondes averaged ?6 mm of ZWD lower than the WVR. After the removal of biases between the techniques, the VLBI and GPS scales differ by less than 3%, while the WVR scale was ?5% higher and the radiosonde scale was ?5% lower. Estimates of zenith wet delay by GPS receivers equipped with Dorne?Margolin choke ring antennas were found to have a strong dependence on the minimum elevation angle of the data. Elevation angle dependent phase errors for the GPS antenna/mount combination can produce ZWD errors of greater than 30 mm over a few hour interval for typical GPS satellite coverage. The VLBI measurements of ZWD are independent of minimum elevation angle and, based on known error sources, appear to be the most accurate of the four techniques.
|
Collections
Show full item record
| contributor author | Niell, A. E. | |
| contributor author | Coster, A. J. | |
| contributor author | Solheim, F. S. | |
| contributor author | Mendes, V. B. | |
| contributor author | Toor, P. C. | |
| contributor author | Langley, R. B. | |
| contributor author | Upham, C. A. | |
| date accessioned | 2017-06-09T14:23:41Z | |
| date available | 2017-06-09T14:23:41Z | |
| date copyright | 2001/06/01 | |
| date issued | 2001 | |
| identifier issn | 0739-0572 | |
| identifier other | ams-1852.pdf | |
| identifier uri | http://onlinelibrary.yabesh.ir/handle/yetl/4154534 | |
| description abstract | The accuracy of the Global Positioning System (GPS) as an instrument for measuring the integrated water vapor content of the atmosphere has been evaluated by comparison with concurrent observations made over a 14-day period by radiosonde, microwave water vapor radiometer (WVR), and Very Long Baseline Interferometry (VLBI). The Vaisala RS-80 A-HUMICAP radiosondes required a correction to the relative humidity readings (provided by Vaisala) to account for packaging contamination; the WVR data required a correction in order to be consistent with the wet refractivity formulation of the VLBI, GPS, and radiosondes. The best agreement of zenith wet delay (ZWD) among the collocated WVR, radiosondes, VLBI, and GPS was for minimum elevations of the GPS measurements below 10°. After corrections were applied to the WVR and radiosonde measurements, WVR, GPS, and VLBI (with 5° minimum elevation angle cutoff) agreed within ?6 mm of ZWD [1 mm of precipitable water vapor (PWV)] when the differences were averaged, while the radiosondes averaged ?6 mm of ZWD lower than the WVR. After the removal of biases between the techniques, the VLBI and GPS scales differ by less than 3%, while the WVR scale was ?5% higher and the radiosonde scale was ?5% lower. Estimates of zenith wet delay by GPS receivers equipped with Dorne?Margolin choke ring antennas were found to have a strong dependence on the minimum elevation angle of the data. Elevation angle dependent phase errors for the GPS antenna/mount combination can produce ZWD errors of greater than 30 mm over a few hour interval for typical GPS satellite coverage. The VLBI measurements of ZWD are independent of minimum elevation angle and, based on known error sources, appear to be the most accurate of the four techniques. | |
| publisher | American Meteorological Society | |
| title | Comparison of Measurements of Atmospheric Wet Delay by Radiosonde, Water Vapor Radiometer, GPS, and VLBI | |
| type | Journal Paper | |
| journal volume | 18 | |
| journal issue | 6 | |
| journal title | Journal of Atmospheric and Oceanic Technology | |
| identifier doi | 10.1175/1520-0426(2001)018<0830:COMOAW>2.0.CO;2 | |
| journal fristpage | 830 | |
| journal lastpage | 850 | |
| tree | Journal of Atmospheric and Oceanic Technology:;2001:;volume( 018 ):;issue: 006 | |
| contenttype | Fulltext |