YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • AMS
    • Journal of Meteorology
    • View Item
    •   YE&T Library
    • AMS
    • Journal of Meteorology
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    THUNDERSTORM CHARGE SEPARATION

    Source: Journal of Meteorology:;1957:;volume( 014 ):;issue: 005::page 426
    Author:
    Reynolds, S. E.
    ,
    Brook, M.
    ,
    Gourley, Mary Foulks
    DOI: 10.1175/1520-0469(1957)014<0426:TCS>2.0.CO;2
    Publisher: American Meteorological Society
    Abstract: A description of the known physical properties of a thunderstorm reveals that active charge separation occurs during that stage of the storm's life-cycle in which the growth of graupel by the accretion of supercooled droplets is the dominant process. Laboratory experiments under simulated thunderstorm conditions show that a graupel pellet, growing by the accretion of supercooled droplets, acquires negative charge as a result of collisions with ice crystals. Other experiments show that when two ice formations are placed in rubbing contact, the ice which is warmer, or which contains trace amounts of contaminants, acquires negative charge. Further experiments suggest that the charge separation results from potential differences which arise during the resolidification of a liquid layer formed at the ice-ice contact. Calculations indicate that the graupel pellets in a thunderstorm, as a result of the acquisition of the latent heat of supercooled droplets, will achieve temperatures several degrees warmer than coexisting ice crystals. Thus the graupel pellets will acquire negative charge as a result of rubbing contacts with ice crystals. The graupel pellets have much higher fall velocities than ice crystals, thus accounting for the polarity of the main thunderstorm dipole. Measurements suggest that the amount of charge separated per graupelcrystal collision is adequate to account for the magnitude of the charges of the main dipole.
    • Download: (1.272Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      THUNDERSTORM CHARGE SEPARATION

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4149926
    Collections
    • Journal of Meteorology

    Show full item record

    contributor authorReynolds, S. E.
    contributor authorBrook, M.
    contributor authorGourley, Mary Foulks
    date accessioned2017-06-09T14:11:43Z
    date available2017-06-09T14:11:43Z
    date copyright1957/10/01
    date issued1957
    identifier issn0095-9634
    identifier otherams-14372.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4149926
    description abstractA description of the known physical properties of a thunderstorm reveals that active charge separation occurs during that stage of the storm's life-cycle in which the growth of graupel by the accretion of supercooled droplets is the dominant process. Laboratory experiments under simulated thunderstorm conditions show that a graupel pellet, growing by the accretion of supercooled droplets, acquires negative charge as a result of collisions with ice crystals. Other experiments show that when two ice formations are placed in rubbing contact, the ice which is warmer, or which contains trace amounts of contaminants, acquires negative charge. Further experiments suggest that the charge separation results from potential differences which arise during the resolidification of a liquid layer formed at the ice-ice contact. Calculations indicate that the graupel pellets in a thunderstorm, as a result of the acquisition of the latent heat of supercooled droplets, will achieve temperatures several degrees warmer than coexisting ice crystals. Thus the graupel pellets will acquire negative charge as a result of rubbing contacts with ice crystals. The graupel pellets have much higher fall velocities than ice crystals, thus accounting for the polarity of the main thunderstorm dipole. Measurements suggest that the amount of charge separated per graupelcrystal collision is adequate to account for the magnitude of the charges of the main dipole.
    publisherAmerican Meteorological Society
    titleTHUNDERSTORM CHARGE SEPARATION
    typeJournal Paper
    journal volume14
    journal issue5
    journal titleJournal of Meteorology
    identifier doi10.1175/1520-0469(1957)014<0426:TCS>2.0.CO;2
    journal fristpage426
    journal lastpage436
    treeJournal of Meteorology:;1957:;volume( 014 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian