YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • AMS
    • Journal of Applied Meteorology
    • View Item
    •   YE&T Library
    • AMS
    • Journal of Applied Meteorology
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    An Integrated Approach toward Retrieving Physically Consistent Profiles of Temperature, Humidity, and Cloud Liquid Water

    Source: Journal of Applied Meteorology:;2004:;volume( 043 ):;issue: 009::page 1295
    Author:
    Löhnert, Ulrich
    ,
    Crewell, Susanne
    ,
    Simmer, Clemens
    DOI: 10.1175/1520-0450(2004)043<1295:AIATRP>2.0.CO;2
    Publisher: American Meteorological Society
    Abstract: A method is presented for deriving physically consistent profiles of temperature, humidity, and cloud liquid water content. This approach combines a ground-based multichannel microwave radiometer, a cloud radar, a lidar-ceilometer, the nearest operational radiosonde measurement, and ground-level measurements of standard meteorological properties with statistics derived from results of a microphysical cloud model. All measurements are integrated within the framework of optimal estimation to guarantee a retrieved profile with maximum information content. The developed integrated profiling technique (IPT) is applied to synthetic cloud model output as a test of accuracy. It is shown that the liquid water content profiles obtained with the IPT are significantly more accurate than common methods that use the microwave-derived liquid water path to scale the radar reflectivity profile. The IPT is also applied to 2 months of the European Cloud Liquid Water Network (CLIWA-NET) Baltic Sea Experiment (BALTEX) BRIDGE main experiment (BBC) campaign data, considering liquid-phase, nonprecipitating clouds only. Error analysis indicates root-mean-square uncertainties of less than 1 K in temperature and less than 1 g m?3 in humidity, where the relative error in liquid water content ranges from 15% to 25%. A comparison of the vertically integrated humidity profile from the IPT with the nearest operational radiosonde shows an acceptable bias error of 0.13 kg m?2 when the Rosenkranz gas absorption model is used. However, if the Liebe gas absorption model is used, this systematic error increases to ?1.24 kg m?2, showing that the IPT humidity retrieval is significantly dependent on the chosen gas absorption model.
    • Download: (599.1Kb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      An Integrated Approach toward Retrieving Physically Consistent Profiles of Temperature, Humidity, and Cloud Liquid Water

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4148851
    Collections
    • Journal of Applied Meteorology

    Show full item record

    contributor authorLöhnert, Ulrich
    contributor authorCrewell, Susanne
    contributor authorSimmer, Clemens
    date accessioned2017-06-09T14:09:16Z
    date available2017-06-09T14:09:16Z
    date copyright2004/09/01
    date issued2004
    identifier issn0894-8763
    identifier otherams-13404.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4148851
    description abstractA method is presented for deriving physically consistent profiles of temperature, humidity, and cloud liquid water content. This approach combines a ground-based multichannel microwave radiometer, a cloud radar, a lidar-ceilometer, the nearest operational radiosonde measurement, and ground-level measurements of standard meteorological properties with statistics derived from results of a microphysical cloud model. All measurements are integrated within the framework of optimal estimation to guarantee a retrieved profile with maximum information content. The developed integrated profiling technique (IPT) is applied to synthetic cloud model output as a test of accuracy. It is shown that the liquid water content profiles obtained with the IPT are significantly more accurate than common methods that use the microwave-derived liquid water path to scale the radar reflectivity profile. The IPT is also applied to 2 months of the European Cloud Liquid Water Network (CLIWA-NET) Baltic Sea Experiment (BALTEX) BRIDGE main experiment (BBC) campaign data, considering liquid-phase, nonprecipitating clouds only. Error analysis indicates root-mean-square uncertainties of less than 1 K in temperature and less than 1 g m?3 in humidity, where the relative error in liquid water content ranges from 15% to 25%. A comparison of the vertically integrated humidity profile from the IPT with the nearest operational radiosonde shows an acceptable bias error of 0.13 kg m?2 when the Rosenkranz gas absorption model is used. However, if the Liebe gas absorption model is used, this systematic error increases to ?1.24 kg m?2, showing that the IPT humidity retrieval is significantly dependent on the chosen gas absorption model.
    publisherAmerican Meteorological Society
    titleAn Integrated Approach toward Retrieving Physically Consistent Profiles of Temperature, Humidity, and Cloud Liquid Water
    typeJournal Paper
    journal volume43
    journal issue9
    journal titleJournal of Applied Meteorology
    identifier doi10.1175/1520-0450(2004)043<1295:AIATRP>2.0.CO;2
    journal fristpage1295
    journal lastpage1307
    treeJournal of Applied Meteorology:;2004:;volume( 043 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian