    Analysis of Small-Scale Convective Dynamics in a Crown Fire Using Infrared Video Camera Imagery

    Source: Journal of Applied Meteorology:;1999:;volume( 038 ):;issue: 010::page 1401
    Author:
    Clark, Terry L.
    ,
    Radke, Larry
    ,
    Coen, Janice
    ,
    Middleton, Don
    DOI: 10.1175/1520-0450(1999)038<1401:AOSSCD>2.0.CO;2
    Publisher: American Meteorological Society
    Abstract: A good physical understanding of the initiation, propagation, and spread of crown fires remains an elusive goal for fire researchers. Although some data exist that describe the fire spread rate and some qualitative aspects of wildfire behavior, none have revealed the very small timescales and spatial scales in the convective processes that may play a key role in determining both the details and the rate of fire spread. Here such a dataset is derived using data from a prescribed burn during the International Crown Fire Modelling Experiment. A gradient-based image flow analysis scheme is presented and applied to a sequence of high-frequency (0.03 s), high-resolution (0.05?0.16 m) radiant temperature images obtained by an Inframetrics ThermaCAM instrument during an intense crown fire to derive wind fields and sensible heat flux. It was found that the motions during the crown fire had energy-containing scales on the order of meters with timescales of fractions of a second. Estimates of maximum vertical heat fluxes ranged between 0.6 and 3 MW m?2 over the 4.5-min burn, with early time periods showing surprisingly large fluxes of 3 MW m?2. Statistically determined velocity extremes, using five standard deviations from the mean, suggest that updrafts between 10 and 30 m s?1, downdrafts between ?10 and ?20 m s?1, and horizontal motions between 5 and 15 m s?1 frequently occurred throughout the fire. The image flow analyses indicated a number of physical mechanisms that contribute to the fire spread rate, such as the enhanced tilting of horizontal vortices leading to counterrotating convective towers with estimated vertical vorticities of 4 to 10 s?1 rotating such that air between the towers blew in the direction of fire spread at canopy height and below. The IR imagery and flow analysis also repeatedly showed regions of thermal saturation (infrared temperature > 750°C), rising through the convection. These regions represent turbulent bursts or hairpin vortices resulting again from vortex tilting but in the sense that the tilted vortices come together to form the hairpin shape. As the vortices rise and come closer together their combined motion results in the vortex tilting forward at a relatively sharp angle, giving a hairpin shape. The development of these hairpin vortices over a range of scales may represent an important mechanism through which convection contributes to the fire spread. A major problem with the IR data analysis is understanding fully what it is that the camera is sampling, in order physically to interpret the data. The results indicate that because of the large amount of after-burning incandescent soot associated with the crown fire, the camera was viewing only a shallow depth into the flame front, and variabilities in the distribution of hot soot particles provide the structures necessary to derive image flow fields. The coherency of the derived horizontal velocities support this view because if the IR camera were seeing deep into or through the flame front, then the effect of the ubiquitous vertical rotations almost certainly would result in random and incoherent estimates for the horizontal flow fields. Animations of the analyzed imagery showed a remarkable level of consistency in both horizontal and vertical velocity flow structures from frame to frame in support of this interpretation. The fact that the 2D image represents a distorted surface also must be taken into account when interpreting the data. Suggestions for further field experimentation, software development, and testing are discussed in the conclusions. These suggestions may further understanding on this topic and increase the utility of this type of analysis to wildfire research.
    • Download: (414.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Analysis of Small-Scale Convective Dynamics in a Crown Fire Using Infrared Video Camera Imagery

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4148147
    Collections
    • Journal of Applied Meteorology

    Show full item record

    contributor authorClark, Terry L.
    contributor authorRadke, Larry
    contributor authorCoen, Janice
    contributor authorMiddleton, Don
    date accessioned2017-06-09T14:07:09Z
    date available2017-06-09T14:07:09Z
    date copyright1999/10/01
    date issued1999
    identifier issn0894-8763
    identifier otherams-12771.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4148147
    description abstractA good physical understanding of the initiation, propagation, and spread of crown fires remains an elusive goal for fire researchers. Although some data exist that describe the fire spread rate and some qualitative aspects of wildfire behavior, none have revealed the very small timescales and spatial scales in the convective processes that may play a key role in determining both the details and the rate of fire spread. Here such a dataset is derived using data from a prescribed burn during the International Crown Fire Modelling Experiment. A gradient-based image flow analysis scheme is presented and applied to a sequence of high-frequency (0.03 s), high-resolution (0.05?0.16 m) radiant temperature images obtained by an Inframetrics ThermaCAM instrument during an intense crown fire to derive wind fields and sensible heat flux. It was found that the motions during the crown fire had energy-containing scales on the order of meters with timescales of fractions of a second. Estimates of maximum vertical heat fluxes ranged between 0.6 and 3 MW m?2 over the 4.5-min burn, with early time periods showing surprisingly large fluxes of 3 MW m?2. Statistically determined velocity extremes, using five standard deviations from the mean, suggest that updrafts between 10 and 30 m s?1, downdrafts between ?10 and ?20 m s?1, and horizontal motions between 5 and 15 m s?1 frequently occurred throughout the fire. The image flow analyses indicated a number of physical mechanisms that contribute to the fire spread rate, such as the enhanced tilting of horizontal vortices leading to counterrotating convective towers with estimated vertical vorticities of 4 to 10 s?1 rotating such that air between the towers blew in the direction of fire spread at canopy height and below. The IR imagery and flow analysis also repeatedly showed regions of thermal saturation (infrared temperature > 750°C), rising through the convection. These regions represent turbulent bursts or hairpin vortices resulting again from vortex tilting but in the sense that the tilted vortices come together to form the hairpin shape. As the vortices rise and come closer together their combined motion results in the vortex tilting forward at a relatively sharp angle, giving a hairpin shape. The development of these hairpin vortices over a range of scales may represent an important mechanism through which convection contributes to the fire spread. A major problem with the IR data analysis is understanding fully what it is that the camera is sampling, in order physically to interpret the data. The results indicate that because of the large amount of after-burning incandescent soot associated with the crown fire, the camera was viewing only a shallow depth into the flame front, and variabilities in the distribution of hot soot particles provide the structures necessary to derive image flow fields. The coherency of the derived horizontal velocities support this view because if the IR camera were seeing deep into or through the flame front, then the effect of the ubiquitous vertical rotations almost certainly would result in random and incoherent estimates for the horizontal flow fields. Animations of the analyzed imagery showed a remarkable level of consistency in both horizontal and vertical velocity flow structures from frame to frame in support of this interpretation. The fact that the 2D image represents a distorted surface also must be taken into account when interpreting the data. Suggestions for further field experimentation, software development, and testing are discussed in the conclusions. These suggestions may further understanding on this topic and increase the utility of this type of analysis to wildfire research.
    publisherAmerican Meteorological Society
    titleAnalysis of Small-Scale Convective Dynamics in a Crown Fire Using Infrared Video Camera Imagery
    typeJournal Paper
    journal volume38
    journal issue10
    journal titleJournal of Applied Meteorology
    identifier doi10.1175/1520-0450(1999)038<1401:AOSSCD>2.0.CO;2
    journal fristpage1401
    journal lastpage1420
    treeJournal of Applied Meteorology:;1999:;volume( 038 ):;issue: 010
    contenttypeFulltext