    A Comparison of Columnar Water Vapor Retrievals Obtained with Near-IR Solar Radiometer and Microwave Radiometer Measurements

    Source: Journal of Applied Meteorology:;1995:;volume( 034 ):;issue: 006::page 1384
    Author:
    Reagan, J.
    ,
    Thome, K.
    ,
    Herman, B.
    ,
    Stone, R.
    ,
    DeLuisi, J.
    ,
    Snider, J.
    DOI: 10.1175/1520-0450(1995)034<1384:ACOCWV>2.0.CO;2
    Publisher: American Meteorological Society
    Abstract: A simple two-channel solar radiometer and analysis technique have been developed for setting atmospheric water vapor via differential solar transmission measurements in and adjacent to the 940-nm water vapor absorption band. A prototype solar radiometer developed for the National Oceanic and Atmospheric Administration (NOAA)/Environmental Research Laboratory underwent trial measurements near Boulder, Colorado, and during the First ISCCP (International Satellite Cloud Climatology Project) Regional Experiment Phase II cirrus intensive field observation program (Coffeyville, Kansas). These measurements provided the convenient opportunity to compare solar radiometer water vapor retrievals with those obtained using NOAA microwave radiometers. The solar radiometer and microwave radiometer retrievals were found to agree to within 0.1 cm most of the time and to within 0.05 cm the majority of the time, yielding a percent difference in the retrievals generally within 10%. Radiosonde soundings, when available, were also found to generally agree with the microwave and solar radiometer retrievals within 0.1 cm.
    • Download: (646.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Comparison of Columnar Water Vapor Retrievals Obtained with Near-IR Solar Radiometer and Microwave Radiometer Measurements

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4147465
    Collections
    • Journal of Applied Meteorology

    Show full item record

    contributor authorReagan, J.
    contributor authorThome, K.
    contributor authorHerman, B.
    contributor authorStone, R.
    contributor authorDeLuisi, J.
    contributor authorSnider, J.
    date accessioned2017-06-09T14:05:14Z
    date available2017-06-09T14:05:14Z
    date copyright1995/06/01
    date issued1995
    identifier issn0894-8763
    identifier otherams-12157.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4147465
    description abstractA simple two-channel solar radiometer and analysis technique have been developed for setting atmospheric water vapor via differential solar transmission measurements in and adjacent to the 940-nm water vapor absorption band. A prototype solar radiometer developed for the National Oceanic and Atmospheric Administration (NOAA)/Environmental Research Laboratory underwent trial measurements near Boulder, Colorado, and during the First ISCCP (International Satellite Cloud Climatology Project) Regional Experiment Phase II cirrus intensive field observation program (Coffeyville, Kansas). These measurements provided the convenient opportunity to compare solar radiometer water vapor retrievals with those obtained using NOAA microwave radiometers. The solar radiometer and microwave radiometer retrievals were found to agree to within 0.1 cm most of the time and to within 0.05 cm the majority of the time, yielding a percent difference in the retrievals generally within 10%. Radiosonde soundings, when available, were also found to generally agree with the microwave and solar radiometer retrievals within 0.1 cm.
    publisherAmerican Meteorological Society
    titleA Comparison of Columnar Water Vapor Retrievals Obtained with Near-IR Solar Radiometer and Microwave Radiometer Measurements
    typeJournal Paper
    journal volume34
    journal issue6
    journal titleJournal of Applied Meteorology
    identifier doi10.1175/1520-0450(1995)034<1384:ACOCWV>2.0.CO;2
    journal fristpage1384
    journal lastpage1391
    treeJournal of Applied Meteorology:;1995:;volume( 034 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian