YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • AMS
    • Journal of Applied Meteorology
    • View Item
    •   YE&T Library
    • AMS
    • Journal of Applied Meteorology
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Retrieval of Total Precipitable Water Using Radiometric Measurements Near 92 and 183 GHz

    Source: Journal of Applied Meteorology:;1989:;volume( 028 ):;issue: 002::page 146
    Author:
    Wang, J. R.
    ,
    Wilheit, T. T.
    ,
    Chang, L. A.
    DOI: 10.1175/1520-0450(1989)028<0146:ROTPWU>2.0.CO;2
    Publisher: American Meteorological Society
    Abstract: The strong water vapor absorption line at 183 GHz is explored in this paper for retrieval of total precipitable water in the atmosphere. This strong line has generally been utilized in the past for the profiling of the atmospheric water vapor. It is shown from radiative transfer calculations that, under very dry atmospheric conditions, the radiometric response near this frequency behaves much like that near the 22 GHz absorption line but, with the advantages of an increase in sensitivity and potentially an improvement in spatial resolution. Total precipitable water can be retrieval almost independent of atmospheric temperature profiles under these conditions. The technique is demonstrated with the airborne Advanced Microwave Moisture Sounder (AMMS) which has four channels, three of them centered around 183 GHz (183 ± 2 GHz, 183 ± 5 GHz, and 183 ± 9 GHz) and another at 92 GHz. The calculated sensitivities of radiometric response to total precipitable water are approximately 410, 230, and 130 K (cm)2 g?1 for total precipitable water less than 0.2, 0.3, and 0.5 g (cm)?2 at 183 ± 2 GHz, 183 ± 5 GHz, and 183 ± 9 GHz respectively. The inclusion of the 92 GHz channel extends the range of the retrieval in excess of 1 g (cm)?2 total precipitable water. However, the effect of cloud cover proves to be strong at this frequency and the retrieval has to be applied with care. Two AMMS observations of dry atmosphere following the cold air outbreaks are analyzed to demonstrate the technique.
    • Download: (693.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Retrieval of Total Precipitable Water Using Radiometric Measurements Near 92 and 183 GHz

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4146645
    Collections
    • Journal of Applied Meteorology

    Show full item record

    contributor authorWang, J. R.
    contributor authorWilheit, T. T.
    contributor authorChang, L. A.
    date accessioned2017-06-09T14:02:37Z
    date available2017-06-09T14:02:37Z
    date copyright1989/02/01
    date issued1989
    identifier issn0894-8763
    identifier otherams-11419.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4146645
    description abstractThe strong water vapor absorption line at 183 GHz is explored in this paper for retrieval of total precipitable water in the atmosphere. This strong line has generally been utilized in the past for the profiling of the atmospheric water vapor. It is shown from radiative transfer calculations that, under very dry atmospheric conditions, the radiometric response near this frequency behaves much like that near the 22 GHz absorption line but, with the advantages of an increase in sensitivity and potentially an improvement in spatial resolution. Total precipitable water can be retrieval almost independent of atmospheric temperature profiles under these conditions. The technique is demonstrated with the airborne Advanced Microwave Moisture Sounder (AMMS) which has four channels, three of them centered around 183 GHz (183 ± 2 GHz, 183 ± 5 GHz, and 183 ± 9 GHz) and another at 92 GHz. The calculated sensitivities of radiometric response to total precipitable water are approximately 410, 230, and 130 K (cm)2 g?1 for total precipitable water less than 0.2, 0.3, and 0.5 g (cm)?2 at 183 ± 2 GHz, 183 ± 5 GHz, and 183 ± 9 GHz respectively. The inclusion of the 92 GHz channel extends the range of the retrieval in excess of 1 g (cm)?2 total precipitable water. However, the effect of cloud cover proves to be strong at this frequency and the retrieval has to be applied with care. Two AMMS observations of dry atmosphere following the cold air outbreaks are analyzed to demonstrate the technique.
    publisherAmerican Meteorological Society
    titleRetrieval of Total Precipitable Water Using Radiometric Measurements Near 92 and 183 GHz
    typeJournal Paper
    journal volume28
    journal issue2
    journal titleJournal of Applied Meteorology
    identifier doi10.1175/1520-0450(1989)028<0146:ROTPWU>2.0.CO;2
    journal fristpage146
    journal lastpage154
    treeJournal of Applied Meteorology:;1989:;volume( 028 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian