    Pressure-Dependent Leak Detection Model and Its Application to a District Water System

    Source: Journal of Water Resources Planning and Management:;2010:;Volume ( 136 ):;issue: 001
    Author:
    Zheng Yi Wu
    ,
    Paul Sage
    ,
    David Turtle
    DOI: 10.1061/(ASCE)0733-9496(2010)136:1(116)
    Publisher: American Society of Civil Engineers
    Abstract: Cost-effective reduction of water loss is a compelling but challenging task for water utilities. This paper presents a model-based optimization method for leakage detection of water distribution systems. Leakage hotspots are assumed to exist at the model nodes identified. Leakage is represented as pressure-dependent demand simulated as emitter flows at selected model nodes. The leakage detection method is formulated to optimize the leakage node locations and their associated emitter coefficients such that the differences between the model predicted and the field observed values for pressure and flow are minimized. The optimization problem is solved by using a competent genetic algorithm. The leakage detection method is developed as an add-on feature of the optimization-based model calibration tool. This enables engineers to undertake leakage hotspot optimization as an independent task or combine the task with hydraulic model calibration, subject to suitably varied field data. Two case studies are discussed in this paper including an example from literature and a district water system in the United Kingdom. The results obtained illustrate that the optimization model for predicting leakage hotspots can be effective despite the recognized challenges of model calibration and the physical measurement limitations from the pressure and flow surveys also referred to as field tests. It is found that the method is effective at being applied for hydraulic conditions that occur in the early hours of the morning, often on water networks with excess design capacity and where hydraulic gradients are slack and loggers may sometimes be working close to their limits of accuracy.
    • Download: (850.9Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Pressure-Dependent Leak Detection Model and Its Application to a District Water System

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/40262
    Collections
    • Journal of Water Resources Planning and Management

    Show full item record

    contributor authorZheng Yi Wu
    contributor authorPaul Sage
    contributor authorDavid Turtle
    date accessioned2017-05-08T21:08:31Z
    date available2017-05-08T21:08:31Z
    date copyrightJanuary 2010
    date issued2010
    identifier other%28asce%290733-9496%282010%29136%3A1%28116%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/40262
    description abstractCost-effective reduction of water loss is a compelling but challenging task for water utilities. This paper presents a model-based optimization method for leakage detection of water distribution systems. Leakage hotspots are assumed to exist at the model nodes identified. Leakage is represented as pressure-dependent demand simulated as emitter flows at selected model nodes. The leakage detection method is formulated to optimize the leakage node locations and their associated emitter coefficients such that the differences between the model predicted and the field observed values for pressure and flow are minimized. The optimization problem is solved by using a competent genetic algorithm. The leakage detection method is developed as an add-on feature of the optimization-based model calibration tool. This enables engineers to undertake leakage hotspot optimization as an independent task or combine the task with hydraulic model calibration, subject to suitably varied field data. Two case studies are discussed in this paper including an example from literature and a district water system in the United Kingdom. The results obtained illustrate that the optimization model for predicting leakage hotspots can be effective despite the recognized challenges of model calibration and the physical measurement limitations from the pressure and flow surveys also referred to as field tests. It is found that the method is effective at being applied for hydraulic conditions that occur in the early hours of the morning, often on water networks with excess design capacity and where hydraulic gradients are slack and loggers may sometimes be working close to their limits of accuracy.
    publisherAmerican Society of Civil Engineers
    titlePressure-Dependent Leak Detection Model and Its Application to a District Water System
    typeJournal Paper
    journal volume136
    journal issue1
    journal titleJournal of Water Resources Planning and Management
    identifier doi10.1061/(ASCE)0733-9496(2010)136:1(116)
    treeJournal of Water Resources Planning and Management:;2010:;Volume ( 136 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian