Identifying Sets of Key Nodes for Placing Sensors in Dynamic Water Distribution NetworksSource: Journal of Water Resources Planning and Management:;2008:;Volume ( 134 ):;issue: 004Author:Jianhua Xu
,
Paul S. Fischbeck
,
Mitchell J. Small
,
Jeanne M. VanBriesen
,
Elizabeth Casman
DOI: 10.1061/(ASCE)0733-9496(2008)134:4(378)Publisher: American Society of Civil Engineers
Abstract: The design of a sensor-placement scheme capable of detecting all possible contamination events for a water distribution system before consumers are put at risk is essentially impossible given current technologies and budgets. It is, however, possible to design sensor-placement schemes that optimize related objectives (e.g., minimize expected volume of contaminated water consumed prior to detection), but this requires the availability of hydraulic and water quality models for the distribution network and significant computational power, which are the main obstacles to the identification of optimal sensor locations. This paper describes a different approach that reduces the problem’s complexity by expressing a water distribution system as different graphs based on the information readily available from most, if not all, water utilities. The approach provides critical policy and decision support for utilities when hydraulic and water quality models are not available and/or when simulation-based techniques are computationally infeasible.
|
Show full item record
contributor author | Jianhua Xu | |
contributor author | Paul S. Fischbeck | |
contributor author | Mitchell J. Small | |
contributor author | Jeanne M. VanBriesen | |
contributor author | Elizabeth Casman | |
date accessioned | 2017-05-08T21:08:22Z | |
date available | 2017-05-08T21:08:22Z | |
date copyright | July 2008 | |
date issued | 2008 | |
identifier other | %28asce%290733-9496%282008%29134%3A4%28378%29.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/40168 | |
description abstract | The design of a sensor-placement scheme capable of detecting all possible contamination events for a water distribution system before consumers are put at risk is essentially impossible given current technologies and budgets. It is, however, possible to design sensor-placement schemes that optimize related objectives (e.g., minimize expected volume of contaminated water consumed prior to detection), but this requires the availability of hydraulic and water quality models for the distribution network and significant computational power, which are the main obstacles to the identification of optimal sensor locations. This paper describes a different approach that reduces the problem’s complexity by expressing a water distribution system as different graphs based on the information readily available from most, if not all, water utilities. The approach provides critical policy and decision support for utilities when hydraulic and water quality models are not available and/or when simulation-based techniques are computationally infeasible. | |
publisher | American Society of Civil Engineers | |
title | Identifying Sets of Key Nodes for Placing Sensors in Dynamic Water Distribution Networks | |
type | Journal Paper | |
journal volume | 134 | |
journal issue | 4 | |
journal title | Journal of Water Resources Planning and Management | |
identifier doi | 10.1061/(ASCE)0733-9496(2008)134:4(378) | |
tree | Journal of Water Resources Planning and Management:;2008:;Volume ( 134 ):;issue: 004 | |
contenttype | Fulltext |