    Strength of Screw Connections in Cold-Formed Steel Construction

    Source: Journal of Structural Engineering:;2009:;Volume ( 135 ):;issue: 008
    Author:
    Reynaud Serrette
    ,
    Dean Peyton
    DOI: 10.1061/(ASCE)0733-9445(2009)135:8(951)
    Publisher: American Society of Civil Engineers
    Abstract: This paper presents a review of the design provisions for screw-fastened cold-formed steel connections in the United States, including criteria for testing and evaluating the strength of screw fasteners. In addition, the paper examines the relationship between the connected elements/components computed connection strength and the strength of the connector (screws). Fastener strength test data from three independent manufacturers is presented and it is shown that as the thickness or yield strength of the connected elements/components is increased, the ratio of the fastener strength to the bearing/tilting strength decreases to values less than one-half in some cases. Analysis of the test data showed that even when the 2001 North American Specification (NASPEC) for the Design of Cold-Formed Steel Structural Members statistical requirements for distribution of the test data are met, the computed safety and resistance factors can exceed the recommended limits in Section E4 of the 2001 NASPEC. On this basis, it is recommended that the current language in the 2001 NASPEC be revised to specify, if necessary, limits on manufacturer computed safety and resistance factors. Finally, it is recommended that fastener tilt during screw shear strength tests be eliminated to facilitate an accurate evaluation of the shear strength of a fastener.
    • Download: (336.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Strength of Screw Connections in Cold-Formed Steel Construction

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/35433
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorReynaud Serrette
    contributor authorDean Peyton
    date accessioned2017-05-08T21:00:54Z
    date available2017-05-08T21:00:54Z
    date copyrightAugust 2009
    date issued2009
    identifier other%28asce%290733-9445%282009%29135%3A8%28951%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/35433
    description abstractThis paper presents a review of the design provisions for screw-fastened cold-formed steel connections in the United States, including criteria for testing and evaluating the strength of screw fasteners. In addition, the paper examines the relationship between the connected elements/components computed connection strength and the strength of the connector (screws). Fastener strength test data from three independent manufacturers is presented and it is shown that as the thickness or yield strength of the connected elements/components is increased, the ratio of the fastener strength to the bearing/tilting strength decreases to values less than one-half in some cases. Analysis of the test data showed that even when the 2001 North American Specification (NASPEC) for the Design of Cold-Formed Steel Structural Members statistical requirements for distribution of the test data are met, the computed safety and resistance factors can exceed the recommended limits in Section E4 of the 2001 NASPEC. On this basis, it is recommended that the current language in the 2001 NASPEC be revised to specify, if necessary, limits on manufacturer computed safety and resistance factors. Finally, it is recommended that fastener tilt during screw shear strength tests be eliminated to facilitate an accurate evaluation of the shear strength of a fastener.
    publisherAmerican Society of Civil Engineers
    titleStrength of Screw Connections in Cold-Formed Steel Construction
    typeJournal Paper
    journal volume135
    journal issue8
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)0733-9445(2009)135:8(951)
    treeJournal of Structural Engineering:;2009:;Volume ( 135 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian