Show simple item record

contributor authorAparna Ghosh
contributor authorBiswajit Basu
date accessioned2017-05-08T21:00:07Z
date available2017-05-08T21:00:07Z
date copyrightDecember 2007
date issued2007
identifier other%28asce%290733-9445%282007%29133%3A12%281848%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/34968
description abstractA closed-form solution for the optimum tuning ratio of a liquid column damper (LCD) that is valid for damped structures subjected to generalized seismic loading is presented. The closed-form expression is based on the extension of the theory of “fixed-point” frequencies for a classical undamped structure-mass damper system to damped structure-nonlinear LCD system. For the specific case of white noise input, the values of optimum tuning ratio have been compared with those obtained from a standard expression.
publisherAmerican Society of Civil Engineers
titleAlternative Approach to Optimal Tuning Parameter of Liquid Column Damper for Seismic Applications
typeJournal Paper
journal volume133
journal issue12
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(2007)133:12(1848)
treeJournal of Structural Engineering:;2007:;Volume ( 133 ):;issue: 012
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record