contributor author | Craig M. Starr | |
contributor author | Theodor Krauthammer | |
date accessioned | 2017-05-08T20:59:29Z | |
date available | 2017-05-08T20:59:29Z | |
date copyright | August 2005 | |
date issued | 2005 | |
identifier other | %28asce%290733-9445%282005%29131%3A8%281178%29.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/34592 | |
description abstract | This study was conducted utilizing precision impact testing to examine the characteristics of force transfer through cladding panels to an underlying structural support frame. Precision impact tests were conducted monitoring force and acceleration data to characterize load transfer. All specimens were considered identical and the impact loading was varied to provide several test conditions. The findings were that cladding systems may provide buildings with an external barrier capable of reducing short duration loading effects. Most test cases indicated an impact force dissipation of approximately 25–50%, depending on loading conditions. | |
publisher | American Society of Civil Engineers | |
title | Cladding-Structure Interaction under Impact Loads | |
type | Journal Paper | |
journal volume | 131 | |
journal issue | 8 | |
journal title | Journal of Structural Engineering | |
identifier doi | 10.1061/(ASCE)0733-9445(2005)131:8(1178) | |
tree | Journal of Structural Engineering:;2005:;Volume ( 131 ):;issue: 008 | |
contenttype | Fulltext | |