    Static Strength of T-Joints Reinforced with Doubler or Collar Plates. I: Experimental Investigations

    Source: Journal of Structural Engineering:;2005:;Volume ( 131 ):;issue: 001
    Author:
    Y. S. Choo
    ,
    G. J. van der Vegte
    ,
    N. Zettlemoyer
    ,
    B. H. Li
    ,
    J. Y. R. Liew
    DOI: 10.1061/(ASCE)0733-9445(2005)131:1(119)
    Publisher: American Society of Civil Engineers
    Abstract: One of the alternatives to enhance the strength of a tubular joint involves the application of doubler or collar plates as reinforcement. In order to gain understanding of the effect of plate reinforcement on the ultimate capacity, an experimental study has been conducted into the static behavior of axially loaded T-joints reinforced with a doubler plate or collar plate. The parameters investigated involve the type of loading (i.e., tension or compression), the configuration (unreinforced, collar plate reinforced, or doubler plate reinforced), the brace-to-chord diameter ratio
    • Download: (896.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Static Strength of T-Joints Reinforced with Doubler or Collar Plates. I: Experimental Investigations

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/34380
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorY. S. Choo
    contributor authorG. J. van der Vegte
    contributor authorN. Zettlemoyer
    contributor authorB. H. Li
    contributor authorJ. Y. R. Liew
    date accessioned2017-05-08T20:59:11Z
    date available2017-05-08T20:59:11Z
    date copyrightJanuary 2005
    date issued2005
    identifier other%28asce%290733-9445%282005%29131%3A1%28119%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/34380
    description abstractOne of the alternatives to enhance the strength of a tubular joint involves the application of doubler or collar plates as reinforcement. In order to gain understanding of the effect of plate reinforcement on the ultimate capacity, an experimental study has been conducted into the static behavior of axially loaded T-joints reinforced with a doubler plate or collar plate. The parameters investigated involve the type of loading (i.e., tension or compression), the configuration (unreinforced, collar plate reinforced, or doubler plate reinforced), the brace-to-chord diameter ratio
    publisherAmerican Society of Civil Engineers
    titleStatic Strength of T-Joints Reinforced with Doubler or Collar Plates. I: Experimental Investigations
    typeJournal Paper
    journal volume131
    journal issue1
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)0733-9445(2005)131:1(119)
    treeJournal of Structural Engineering:;2005:;Volume ( 131 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian