    Effective Flange Width Definition for Steel–Concrete Composite Bridge Girder

    Source: Journal of Structural Engineering:;2004:;Volume ( 130 ):;issue: 012
    Author:
    Methee Chiewanichakorn
    ,
    Amjad J. Aref
    ,
    Stuart S. Chen
    ,
    Il-Sang Ahn
    DOI: 10.1061/(ASCE)0733-9445(2004)130:12(2016)
    Publisher: American Society of Civil Engineers
    Abstract: A composite section is made up of a concrete slab attached to a steel girder by means of shear connectors. Under positive bending moment, part of the slab will act as the flange of the girder resisting the longitudinal compression. When the spacing between the girders becomes large, it is evident that simple beam theory does not strictly apply because the longitudinal compressive stress in the flange will vary with distance from the girder web, the flange being more highly stressed over the web than in the extremities. This phenomenon is termed “shear lag.” For design purposes, the effective flange width was introduced into national and international design specifications, whereby various effective flange width formulae were derived based on different analytical and experimental results. Accordingly, the effective flange width is generally less than unity, which is not realistic for a small girder spacing. In current effective flange width for mulae, the theoretical derivation is based primarily on a planar stress distribution reflecting shear lag at the central fiber of the concrete. However, this simplification ignores the fact that stresses vary through the thickness. This through-thickness variation needs to be taken into account to produce a more viable representation of effective flange width criteria. Hence, the need for a different definition of the effective flange width becomes apparent. This paper proposes a different method for defining the effective flange width for the composite section, which can be utilized with the results obtained from the finite-element analysis. A three dimensional finite-element model of the composite bridge is verified, and a numerical example illustrating the proposed effective flange width definition is provided.
    • Download: (443.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Effective Flange Width Definition for Steel–Concrete Composite Bridge Girder

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/34222
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorMethee Chiewanichakorn
    contributor authorAmjad J. Aref
    contributor authorStuart S. Chen
    contributor authorIl-Sang Ahn
    date accessioned2017-05-08T20:58:55Z
    date available2017-05-08T20:58:55Z
    date copyrightDecember 2004
    date issued2004
    identifier other%28asce%290733-9445%282004%29130%3A12%282016%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/34222
    description abstractA composite section is made up of a concrete slab attached to a steel girder by means of shear connectors. Under positive bending moment, part of the slab will act as the flange of the girder resisting the longitudinal compression. When the spacing between the girders becomes large, it is evident that simple beam theory does not strictly apply because the longitudinal compressive stress in the flange will vary with distance from the girder web, the flange being more highly stressed over the web than in the extremities. This phenomenon is termed “shear lag.” For design purposes, the effective flange width was introduced into national and international design specifications, whereby various effective flange width formulae were derived based on different analytical and experimental results. Accordingly, the effective flange width is generally less than unity, which is not realistic for a small girder spacing. In current effective flange width for mulae, the theoretical derivation is based primarily on a planar stress distribution reflecting shear lag at the central fiber of the concrete. However, this simplification ignores the fact that stresses vary through the thickness. This through-thickness variation needs to be taken into account to produce a more viable representation of effective flange width criteria. Hence, the need for a different definition of the effective flange width becomes apparent. This paper proposes a different method for defining the effective flange width for the composite section, which can be utilized with the results obtained from the finite-element analysis. A three dimensional finite-element model of the composite bridge is verified, and a numerical example illustrating the proposed effective flange width definition is provided.
    publisherAmerican Society of Civil Engineers
    titleEffective Flange Width Definition for Steel–Concrete Composite Bridge Girder
    typeJournal Paper
    journal volume130
    journal issue12
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)0733-9445(2004)130:12(2016)
    treeJournal of Structural Engineering:;2004:;Volume ( 130 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian