    Seismic Performance Evaluation of Pre-Northridge Steel Frame Buildings with Brittle Connections

    Source: Journal of Structural Engineering:;2002:;Volume ( 128 ):;issue: 004
    Author:
    Kīhak Lee
    ,
    Douglas A. Foutch
    DOI: 10.1061/(ASCE)0733-9445(2002)128:4(546)
    Publisher: American Society of Civil Engineers
    Abstract: As part of the (FEMA/SAC) Phase 2 program, this study focused on performance prediction and evaluation of existing steel SMRF buildings assumed to be built prior to the Northridge Earthquake. Several classes of buildings, which are representative of typical buildings based on year of construction and brittle pre-Northridge connections, were designed in accordance with the 1973, 1985, and 1994 UBC provisions. Then, the frame analysis models were developed including the effects of brittle connections, panel zone deformation, and interior gravity frames. Based on the drift demands and capacities calculated using each set of 20 SAC ground motions representing 2/50 and 50/50 hazard levels, a performance prediction and evaluation procedure based on the reliability framework is presented. Confidence levels that existing buildings will exceed the predefined performance level for different hazard levels are calculated. The pre-Northridge design and construction represented by the old building codes and brittle connections force the buildings to experience large seismic demand and result in a low confidence level in achieving the desired performance levels.
    • Download: (176.9Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Seismic Performance Evaluation of Pre-Northridge Steel Frame Buildings with Brittle Connections

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/33818
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorKīhak Lee
    contributor authorDouglas A. Foutch
    date accessioned2017-05-08T20:58:20Z
    date available2017-05-08T20:58:20Z
    date copyrightApril 2002
    date issued2002
    identifier other%28asce%290733-9445%282002%29128%3A4%28546%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/33818
    description abstractAs part of the (FEMA/SAC) Phase 2 program, this study focused on performance prediction and evaluation of existing steel SMRF buildings assumed to be built prior to the Northridge Earthquake. Several classes of buildings, which are representative of typical buildings based on year of construction and brittle pre-Northridge connections, were designed in accordance with the 1973, 1985, and 1994 UBC provisions. Then, the frame analysis models were developed including the effects of brittle connections, panel zone deformation, and interior gravity frames. Based on the drift demands and capacities calculated using each set of 20 SAC ground motions representing 2/50 and 50/50 hazard levels, a performance prediction and evaluation procedure based on the reliability framework is presented. Confidence levels that existing buildings will exceed the predefined performance level for different hazard levels are calculated. The pre-Northridge design and construction represented by the old building codes and brittle connections force the buildings to experience large seismic demand and result in a low confidence level in achieving the desired performance levels.
    publisherAmerican Society of Civil Engineers
    titleSeismic Performance Evaluation of Pre-Northridge Steel Frame Buildings with Brittle Connections
    typeJournal Paper
    journal volume128
    journal issue4
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)0733-9445(2002)128:4(546)
    treeJournal of Structural Engineering:;2002:;Volume ( 128 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian