    Cyclic Response and Design Recommendations of Reduced Beam Section Moment Connections with Deep Columns

    Source: Journal of Structural Engineering:;2002:;Volume ( 128 ):;issue: 004
    Author:
    Brandon Chi
    ,
    Chia-Ming Uang
    DOI: 10.1061/(ASCE)0733-9445(2002)128:4(464)
    Publisher: American Society of Civil Engineers
    Abstract: Design engineers frequently use deep columns in steel special moment resisting frames to control drift. As the reduced beam section (RBS) moment connection is becoming popular after the 1994 Northridge, California earthquake, the SAC Joint Venture initiated a testing program to study the cyclic behavior of deep-column RBS moment connections. The test results showed that the deep column is prone to twisting. The twisting was caused by the eccentric beam flange force due to lateral-torsional buckling of the beam. In this paper, cycle tests results of three RBS moment connections with deep columns are presented. An analytical study showed that the warping stress is highly dependent on the
    • Download: (653.5Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Cyclic Response and Design Recommendations of Reduced Beam Section Moment Connections with Deep Columns

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/33808
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorBrandon Chi
    contributor authorChia-Ming Uang
    date accessioned2017-05-08T20:58:19Z
    date available2017-05-08T20:58:19Z
    date copyrightApril 2002
    date issued2002
    identifier other%28asce%290733-9445%282002%29128%3A4%28464%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/33808
    description abstractDesign engineers frequently use deep columns in steel special moment resisting frames to control drift. As the reduced beam section (RBS) moment connection is becoming popular after the 1994 Northridge, California earthquake, the SAC Joint Venture initiated a testing program to study the cyclic behavior of deep-column RBS moment connections. The test results showed that the deep column is prone to twisting. The twisting was caused by the eccentric beam flange force due to lateral-torsional buckling of the beam. In this paper, cycle tests results of three RBS moment connections with deep columns are presented. An analytical study showed that the warping stress is highly dependent on the
    publisherAmerican Society of Civil Engineers
    titleCyclic Response and Design Recommendations of Reduced Beam Section Moment Connections with Deep Columns
    typeJournal Paper
    journal volume128
    journal issue4
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)0733-9445(2002)128:4(464)
    treeJournal of Structural Engineering:;2002:;Volume ( 128 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian