| contributor author | Lawrence C. C. Koe | |
| contributor author | Derek K. Brady | |
| date accessioned | 2017-05-08T20:57:43Z | |
| date available | 2017-05-08T20:57:43Z | |
| date copyright | April 1986 | |
| date issued | 1986 | |
| identifier other | %28asce%290733-9372%281986%29112%3A2%28311%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/33431 | |
| description abstract | Procedures for measuring sewage odor are examined and a standard odor unit is recommended for odor quantification of a mixture of odorous gases. Field experiments involving simultaneous measurements of odor and hydrogen sulfide levels at two wastewater sites handling significantly different types of wastes were carried out. Odor level was measured with a dynamic olfactometer, while hydrogen sulfide concentration was determined with a paper‐tape densitometer. Results reveal that the odor concentration | |
| publisher | American Society of Civil Engineers | |
| title | Olfactory Quantification of Sewage Odors | |
| type | Journal Paper | |
| journal volume | 112 | |
| journal issue | 2 | |
| journal title | Journal of Environmental Engineering | |
| identifier doi | 10.1061/(ASCE)0733-9372(1986)112:2(311) | |
| tree | Journal of Environmental Engineering:;1986:;Volume ( 112 ):;issue: 002 | |
| contenttype | Fulltext | |