    Lateral Resistance of Wood Shear Walls with Large Sheathing Panels

    Source: Journal of Structural Engineering:;1997:;Volume ( 123 ):;issue: 012
    Author:
    Frank Lam
    ,
    Helmut G. L. Prion
    ,
    Ming He
    DOI: 10.1061/(ASCE)0733-9445(1997)123:12(1666)
    Publisher: American Society of Civil Engineers
    Abstract: This paper summarizes results from the first phase of a study to evaluate the lateral resistance of wood based shear walls without openings, built with regular and nonstandard large dimension oriented strand board panels under monotonic and cyclic loading conditions. Furthermore, different types and spacings of panel-frame connectors were investigated. Results of the second phase, which considered shear walls with openings, are presented in a subsequent paper. The results of the first phase indicate that under monotonic loading, a substantial increase in both stiffness and lateral load carrying capacity, as well as comparable ductility ratios, can be achieved by shear walls built with oversize panels, compared to regular panels. The walls built with regular panels, however, were found to dissipate more energy under cyclic loading than the walls built with oversize panels. The failure modes were substantially different under monotonic (nail withdrawal) and cyclic (nail fatigue) test conditions, which raised the question as to whether the adopted cyclic loading schedules realistically represent the loading sequence expected under wind and earthquake loading.
    • Download: (1.000Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Lateral Resistance of Wood Shear Walls with Large Sheathing Panels

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/32637
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorFrank Lam
    contributor authorHelmut G. L. Prion
    contributor authorMing He
    date accessioned2017-05-08T20:56:35Z
    date available2017-05-08T20:56:35Z
    date copyrightDecember 1997
    date issued1997
    identifier other%28asce%290733-9445%281997%29123%3A12%281666%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/32637
    description abstractThis paper summarizes results from the first phase of a study to evaluate the lateral resistance of wood based shear walls without openings, built with regular and nonstandard large dimension oriented strand board panels under monotonic and cyclic loading conditions. Furthermore, different types and spacings of panel-frame connectors were investigated. Results of the second phase, which considered shear walls with openings, are presented in a subsequent paper. The results of the first phase indicate that under monotonic loading, a substantial increase in both stiffness and lateral load carrying capacity, as well as comparable ductility ratios, can be achieved by shear walls built with oversize panels, compared to regular panels. The walls built with regular panels, however, were found to dissipate more energy under cyclic loading than the walls built with oversize panels. The failure modes were substantially different under monotonic (nail withdrawal) and cyclic (nail fatigue) test conditions, which raised the question as to whether the adopted cyclic loading schedules realistically represent the loading sequence expected under wind and earthquake loading.
    publisherAmerican Society of Civil Engineers
    titleLateral Resistance of Wood Shear Walls with Large Sheathing Panels
    typeJournal Paper
    journal volume123
    journal issue12
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)0733-9445(1997)123:12(1666)
    treeJournal of Structural Engineering:;1997:;Volume ( 123 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian